Abstract

Many reduced-switch-count (RSC) inverter topologies have been proposed in the literature. As the number of switches required to produce a set of voltages in RSC inverters are less than that in conventional inverter, as a result utilizing RSC inverters in a certain system reduces its size and cost. In this paper, a novel RSC shared inverter topology consisting of fifteen switches and capable of driving four three-phase AC-loads independently is proposed and experimentally verified. A carrier-based pulse width modulation (PWM) technique that employs the zero-sequence-signal injection principle is developed to drive the proposed inverter along with adequate DC voltage bus utilization between the shared loads for common frequency (CF) as well as different frequency (DF) modes. The structure and the principle of operation of the proposed inverter are introduced and intensively verified using simulation and field-programmable-gate-array (FPGA)-in-the-loop simulation under linear and nonlinear loads. Then, Inverter prototype was built and the proposed inverter has been verified experimentally. The experimental results verify the applicability of the proposed inverter and the employed PWM.

Collaboration network of the authors

11 authors · 27 co-authorship links · 22 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Jordan University of Science and Technology
  • Yarmouk University
  • Tafila Technical University
  • Philadelphia University
  • Princess Sumaya University for Technology
  • Jouf University
  • University of Akron
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Muwaffaq I. AlomoushYarmouk University1
Ahmed KoranYarmouk University1
Salman HarasisTafila Technical University1
Eyad K. AlmaitaTafila Technical University1
Khaled AlzaareerPhiladelphia University1
Qusay SalemPrincess Sumaya University for Technology1
Mamdouh L. AlghaythiJouf University1
Mohammad Arifur RahmanUniversity of Akron1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Experimental Validation of Shared Inverter Topology to Drive Multi AC-Loads</dc:title><dc:creator>Albatran, Saher</dc:creator><dc:creator>Smadi, Issam A.</dc:creator><dc:creator>Alsyouf, Mohammad A.</dc:creator><dc:description>&lt;jats:p&gt;Many reduced-switch-count (RSC) inverter topologies have been proposed in the literature. As the number of switches required to produce a set of voltages in RSC inverters are less than that in conventional inverter, as a result utilizing RSC inverters in a certain system reduces its size and cost. In this paper, a novel RSC shared inverter topology consisting of fifteen switches and capable of driving four three-phase AC-loads independently is proposed and experimentally verified. A carrier-based pulse width modulation (PWM) technique that employs the zero-sequence-signal injection principle is developed to drive the proposed inverter along with adequate DC voltage bus utilization between the shared loads for common frequency (CF) as well as different frequency (DF) modes. The structure and the principle of operation of the proposed inverter are introduced and intensively verified using simulation and field-programmable-gate-array (FPGA)-in-the-loop simulation under linear and nonlinear loads. Then, Inverter prototype was built and the proposed inverter has been verified experimentally. The experimental results verify the applicability of the proposed inverter and the employed PWM.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i2.pp793-805</dc:identifier><dc:identifier>10.11591/ijece.v8i2.pp793-805</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 2 (2018); 793</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/9967/9191</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>