Abstract

This paper describes the importance of FACTS devices; it presents the outcome of the study of its reflectance on the performance of power system networks. It seeks to increase and guarantee the fact and accuracy of response systems under disturbance conditions when the phase measurement units are introduced as Real-Time Measurement (RTM) stations. This paper also describes the importance of FACTS devices. The combination of FACTS devices and PMUs is presented to increase the controllability performance of power systems. This paper demonstrates how PMUs measure voltage, current and their angles. It provides, through a communication link, a Phase Angle Data Concentrator (PDC) to make an appropriate decision to correct the power system state using the FACTS device (TCSC). We utilized the Graph-Theoretic Algorithm to optimize the number and location of PMUs. The technique proposed was tested on the Iraqi National Super Grid’s 24bus network, Diyala City’s regional 10bus network and the 14bus IEEE standard test system. The MATLAB/PSAT package was utilized for the simulation of results. It is evident that our proposed algorithm and technique achieved the purpose of this paper as confirmed by the level of accuracy of the results obtained from most of the cases tested.

Collaboration network of the authors

13 authors · 24 co-authorship links · 9 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Diyala
  • University of Anbar
  • Universidad de Málaga
  • Universiti Tenaga Nasional
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ahmed Majeed GhadbanAffiliation unknown2
Mushtaq NajeebUniversity of Anbar1
Muhamad MansorUniversiti Tenaga Nasional1
Hameed FeyadUniversity of Anbar1
Esam Taha YassenUniversity of Anbar1
Hatim Ghadhban AboodUniversity of Diyala1
Mayyadah Sahib IbrahimUniversity of Diyala1
Ahmed Majeed GhadbanAffiliation unknown1
Alejandro RodríguezUniversidad de Málaga1
Francisco Jesús Muñoz GutiérrezUniversidad de Málaga1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Phase Measurement Units based FACT’s Devices for the Improvement of Power Systems Networks Controllability</dc:title><dc:creator>Hussein, Husham Idan</dc:creator><dc:creator>Salman, Ghassan Abdullah</dc:creator><dc:creator>Hasan, Mohammed Saadi</dc:creator><dc:description>&lt;jats:p&gt;This paper describes the importance of FACTS devices; it presents the outcome of the study of its reflectance on the performance of power system networks. It seeks to increase and guarantee the fact and accuracy of response systems under disturbance conditions when the phase measurement units are introduced as Real-Time Measurement (RTM) stations. This paper also describes the importance of FACTS devices. The combination of FACTS devices and PMUs is presented to increase the controllability performance of power systems. This paper demonstrates how PMUs measure voltage, current and their angles. It provides, through a communication link, a Phase Angle Data Concentrator (PDC) to make an appropriate decision to correct the power system state using the FACTS device (TCSC). We utilized the Graph-Theoretic Algorithm to optimize the number and location of PMUs. The technique proposed was tested on the Iraqi National Super Grid’s 24bus network, Diyala City’s regional 10bus network and the 14bus IEEE standard test system. The MATLAB/PSAT package was utilized for the simulation of results. It is evident that our proposed algorithm and technique achieved the purpose of this paper as confirmed by the level of accuracy of the results obtained from most of the cases tested.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i2.pp888-899</dc:identifier><dc:identifier>10.11591/ijece.v8i2.pp888-899</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 2 (2018); 888</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8657/8330</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>