Melola Discovery

← Melola Discovery

Jurnal

THE EFFECT OF IMPLANT DIAMETER ON STRESS, STRAIN, AND SAFETY FACTOR IN SCREWS AND ABUTMENTS BASED ON FEA

Jurnal Pendidikan Teknik Mesin · Vol. 26 No. 01 (2026) · hlm. 1–10

DOI
10.15294/jptm.v26i01.29461
ISSN
2503-1759, 2503-1759
Terbit
2026-08-10
Penerbit
Universitas Negeri Semarang
Bahasa
eng

Abstrak

The loss of anterior teeth has a significant impact on masticatory function and facial aesthetics, making dental implants a widely used rehabilitative solution. The success of implants is greatly influenced by geometric design, particularly the diameter of the fixture, which plays a role in distributing load. This study aims to analyze the influence of variations in implant diameter on stress distribution, strain, and safety factor in the screw and abutment areas using a three-dimensional Finite Element Analysis (FEA) approach. Three implant models with fixture diameters of 3.75 mm, 4.00 mm, and 5.00 mm were simulated using a vertical physiological load of 130.5 ± 73.6 N, assuming Ti-6Al-4V material and orthotropic properties of the mandibular bone. The results showed that Model 2 (4.00 mm diameter) had the most balanced stress distribution and the highest safety factor value at the abutment (12.251), while Model 3 exhibited the lowest stress and strain at the screw. Model 1 had the lowest biomechanical performance with the highest stress and strain and the lowest abutment safety factor (10.611). It can be concluded that variations in fixture diameter significantly affect the mechanical performance of the implant system, and a diameter of 4.00 mm is recommended as the most optimal design to support long-term strength and stability.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 165 tautan kepenulisan bersama · 74 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Diponegoro University
  • Universiti Malaysia Sarawak
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
DhiaulhaqueDiponegoro University10
Rahmat Doni WidodoState University of Semarang7
J. JamariDiponegoro University7
Mohd Syahmi JamaludinUniversiti Malaysia Sarawak7
KriswantoAfiliasi tidak diketahui4
Khoirul HudaState University of Semarang4
Febri Budi DarsonoState University of Semarang4
Fatkhu AmanullohState University of Semarang4
Dzikra Adi PratamaState University of Semarang4
Deni Fajar FitriyanaState University of Semarang3
Dennis Andhara PutraState University of Semarang3
Nurul FatullohState University of Semarang3
Alifian Bagas SaputraState University of Semarang3
Septian Eko CahyonoState University of Semarang3
Hastaka Juan Pratama PutraState University of Semarang3
Januar Parlaungan SiregarUniversiti Malaysia Pahang Al-Sultan Abdullah2
J. JamariDiponegoro University2
Septian Eko CahyantoState University of Semarang2
Beni Aji SubektiState University of Semarang2
Muhammad Iqbal RamadhaniState University of Semarang2
Muhammad Ainun AtharState University of Semarang1
Khoirul HudaState University of Semarang1
Kriswanto KriswantoState University of Semarang1
Galih TriLaksonoState University of Semarang1
Muhammad KhumaediState University of Semarang1
Muhamad Reza Wahyu PrasetyoState University of Semarang1
Tegar Oki PrasdikaState University of Semarang1
Fadhil Putra RamadhanState University of Semarang1
Kaleb PriyantoState University of Semarang1
Rachael AndikaState University of Semarang1
Andrean Rachman RizaldyState University of Semarang1
Agus PrasetyoDiponegoro University1
Risky IsmailAfiliasi tidak diketahui1
Samsudin AnisState University of Semarang1
Muhammad AfrizalDiponegoro University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/JPTM/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">THE EFFECT OF IMPLANT DIAMETER ON STRESS, STRAIN, AND SAFETY FACTOR IN SCREWS AND ABUTMENTS BASED ON FEA</dc:title>
	<dc:creator xml:lang="en">gunagung syahrul nizam sulkan</dc:creator>
	<dc:creator xml:lang="en">Kriswanto</dc:creator>
	<dc:creator xml:lang="en">Ruben Bayu Kristiawan</dc:creator>
	<dc:creator xml:lang="en">Jamari</dc:creator>
	<dc:creator xml:lang="en">Athanasius Priharyoto Bayuseno</dc:creator>
	<dc:subject xml:lang="en">von mises</dc:subject>
	<dc:subject xml:lang="en">safety factor</dc:subject>
	<dc:subject xml:lang="en">finite element analisys</dc:subject>
	<dc:subject xml:lang="en">implant dental</dc:subject>
	<dc:description xml:lang="en">The loss of anterior teeth has a significant impact on masticatory function and facial aesthetics, making dental implants a widely used rehabilitative solution. The success of implants is greatly influenced by geometric design, particularly the diameter of the fixture, which plays a role in distributing load. This study aims to analyze the influence of variations in implant diameter on stress distribution, strain, and safety factor in the screw and abutment areas using a three-dimensional Finite Element Analysis (FEA) approach. Three implant models with fixture diameters of 3.75 mm, 4.00 mm, and 5.00 mm were simulated using a vertical physiological load of 130.5 ± 73.6 N, assuming Ti-6Al-4V material and orthotropic properties of the mandibular bone. The results showed that Model 2 (4.00 mm diameter) had the most balanced stress distribution and the highest safety factor value at the abutment (12.251), while Model 3 exhibited the lowest stress and strain at the screw. Model 1 had the lowest biomechanical performance with the highest stress and strain and the lowest abutment safety factor (10.611). It can be concluded that variations in fixture diameter significantly affect the mechanical performance of the implant system, and a diameter of 4.00 mm is recommended as the most optimal design to support long-term strength and stability.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/JPTM/article/view/29461</dc:identifier>
	<dc:identifier>10.15294/jptm.v26i01.29461</dc:identifier>
	<dc:source xml:lang="en">Jurnal Pendidikan Teknik Mesin; Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"; 1 - 10</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>10.15294/jptm.v26i01</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/JPTM/article/view/29461/11027</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Pendidikan Teknik Mesin</dc:rights>
</oai_dc:dc>