Melola Discovery

← Melola Discovery

Jurnal

FIXTURE DIAMETER INFLUENCE ON BIOMECHANICAL PERFORMANCE OF DENTAL IMPLANT ABUTMENT AND SCREW: A 3D FEA STUDY

Jurnal Pendidikan Teknik Mesin · Vol. 26 No. 01 (2026) · hlm. 11–21

DOI
10.15294/jptm.v26i01.29583
ISSN
2503-1759, 2503-1759
Terbit
2026-08-10
Penerbit
Universitas Negeri Semarang
Bahasa
eng

Abstrak

Dental implant stability hinges on fixture design, particularly diameter, influencing biomechanical performance. This study evaluates the impact of fixture diameter on von Mises stress, strain, and factor of safety in the abutment and screw of posterior dental implants using finite element analysis. A three-dimensional model of a mandibular first molar implant was developed with fixture diameters of 3.75, 4.0, and 5.0 millimeters, using Ti-6Al-4V and static loading simulating maximum voluntary clenching (177.38 N). Results show that the 5.0-millimeter diameter with a wider abutment reduces stress by 23.7 percent in the abutment and 33.9 percent in the screw, strain by 23.7 and 33.1 percent, respectively, and improves factor of safety, compared to 3.75 millimeters. The 5.0-millimeter diameter optimizes biomechanical stability, enhancing long-term implant success in posterior mandibular applications.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 196 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Halu Oleo
  • State University of Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
JamariAfiliasi tidak diketahui9
Febri Budi DarsonoAfiliasi tidak diketahui9
DhiaulhaqueAfiliasi tidak diketahui7
Ruben Bayu KristiawanAfiliasi tidak diketahui5
Septian Eko CahyantoAfiliasi tidak diketahui5
Mohd Syahmi JamaludinAfiliasi tidak diketahui5
Muhammad KhumaediAfiliasi tidak diketahui3
Wirawan SumbodoAfiliasi tidak diketahui3
Khoirudin FathoniState University of Semarang2
AbdurrahmanAfiliasi tidak diketahui2
MUHAMMAD NUR FAIZINAfiliasi tidak diketahui2
Atta Putra HarjantoAfiliasi tidak diketahui2
R. Imanu Danar HerunandiAfiliasi tidak diketahui2
R. Ambar Kuntoro Mursit GendroyonoAfiliasi tidak diketahui2
Kriswanto KriswantoAfiliasi tidak diketahui2
Heri YudionoAfiliasi tidak diketahui2
Rizki SetiadiAfiliasi tidak diketahui2
Ambo UpeUniversitas Halu Oleo1
Faturachman Alputra SudirmanUniversitas Halu Oleo1
Muhammad BasriAfiliasi tidak diketahui1
Elsye GunawanAfiliasi tidak diketahui1
Qonita A. NisaAfiliasi tidak diketahui1
Yuliana R. YabansabraAfiliasi tidak diketahui1
Tatang SutarmanAfiliasi tidak diketahui1
Andre M. WorabaiAfiliasi tidak diketahui1
Dimas A. SyafrudinAfiliasi tidak diketahui1
Fadil M. Al RidhaAfiliasi tidak diketahui1
Karlin MansumberAfiliasi tidak diketahui1
Kristina I. RahailAfiliasi tidak diketahui1
Marselina E. KotenAfiliasi tidak diketahui1
Muhammad M. KhalilAfiliasi tidak diketahui1
Ota M. RumainumAfiliasi tidak diketahui1
Pitera WendaAfiliasi tidak diketahui1
Sarhana R.A. SaidAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/JPTM/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 5 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">FIXTURE DIAMETER INFLUENCE ON BIOMECHANICAL PERFORMANCE OF DENTAL IMPLANT ABUTMENT AND SCREW: A 3D FEA STUDY</dc:title>
	<dc:creator xml:lang="en">Rachael Andika</dc:creator>
	<dc:creator xml:lang="en">Kriswanto</dc:creator>
	<dc:creator xml:lang="en">Khoirul Huda</dc:creator>
	<dc:creator xml:lang="en">Rahmat Doni Widodo</dc:creator>
	<dc:creator xml:lang="en">J. Jamari</dc:creator>
	<dc:creator xml:lang="en">Athanasius Priharyoto Bayuseno</dc:creator>
	<dc:subject xml:lang="en">Dental implant</dc:subject>
	<dc:subject xml:lang="en">fixture diameter</dc:subject>
	<dc:subject xml:lang="en">finite element analysis</dc:subject>
	<dc:subject xml:lang="en">biomechanical stability</dc:subject>
	<dc:description xml:lang="en">Dental implant stability hinges on fixture design, particularly diameter, influencing biomechanical performance. This study evaluates the impact of fixture diameter on von Mises stress, strain, and factor of safety in the abutment and screw of posterior dental implants using finite element analysis. A three-dimensional model of a mandibular first molar implant was developed with fixture diameters of 3.75, 4.0, and 5.0 millimeters, using Ti-6Al-4V and static loading simulating maximum voluntary clenching (177.38 N). Results show that the 5.0-millimeter diameter with a wider abutment reduces stress by 23.7 percent in the abutment and 33.9 percent in the screw, strain by 23.7 and 33.1 percent, respectively, and improves factor of safety, compared to 3.75 millimeters. The 5.0-millimeter diameter optimizes biomechanical stability, enhancing long-term implant success in posterior mandibular applications.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/JPTM/article/view/29583</dc:identifier>
	<dc:identifier>10.15294/jptm.v26i01.29583</dc:identifier>
	<dc:source xml:lang="en">Jurnal Pendidikan Teknik Mesin; Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"; 11 -21</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>10.15294/jptm.v26i01</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/JPTM/article/view/29583/11028</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Pendidikan Teknik Mesin</dc:rights>
</oai_dc:dc>