Numerical simulation-based biomechanical evaluation was used to analyze the effect of implant diameter variation on stress and strain on the abutment and screw using the Finite Element Method (FEM). Modeling was performed based on CBCT data and simulated in ANSYS Workbench 2023 R1. Three implant diameters were tested (3.75 mm, 4.3 mm, and 5.0 mm), each subjected to a force of 204.1 N at a 45° angle to mimic anterior functional conditions. The 4.3 mm diameter produced the highest stress on the abutment (213.62 MPa), while the 5.0 mm diameter showed the lowest stress (192.5 MPa) and minimum strain (0.00178). The 5.0 mm diameter also reduced the load on the screw, indicating a more stable load distribution. Therefore, this diameter is recommended as the optimal biomechanical configuration for anterior implant bridges, while considering anatomical limitations.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 157 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
JamariAfiliasi tidak diketahui8
Khoirul HudaAfiliasi tidak diketahui7
DhiaulhaqueAfiliasi tidak diketahui6
Ruben Bayu KristiawanAfiliasi tidak diketahui5
Septian Eko CahyantoAfiliasi tidak diketahui5
Muhammad Iqbal RamadhaniAfiliasi tidak diketahui5
Mohd Syahmi JamaludinAfiliasi tidak diketahui4
Fadhil Putra RamadhanAfiliasi tidak diketahui4
Kaleb PriyantoAfiliasi tidak diketahui4
Rachael AndikaAfiliasi tidak diketahui4
Andrean Rachman RizaldyAfiliasi tidak diketahui4
Muhammad KhumaediAfiliasi tidak diketahui3
Wirawan SumbodoAfiliasi tidak diketahui2
Heri YudionoAfiliasi tidak diketahui2
gunagung syahrul nizam sulkanAfiliasi tidak diketahui2
Fatkhu AmanullohAfiliasi tidak diketahui2
Dzikra Adi PratamaAfiliasi tidak diketahui2
Dennis Andhara PutraAfiliasi tidak diketahui2
Nurul FatullohAfiliasi tidak diketahui2
Sudibtia Titio KoinAfiliasi tidak diketahui1
Akhmad NurdinAfiliasi tidak diketahui1
Khoirudin FathoniState University of Semarang1
AbdurrahmanAfiliasi tidak diketahui1
MUHAMMAD NUR FAIZINAfiliasi tidak diketahui1
Atta Putra HarjantoAfiliasi tidak diketahui1
R. Imanu Danar HerunandiAfiliasi tidak diketahui1
R. Ambar Kuntoro Mursit GendroyonoAfiliasi tidak diketahui1
Nugroho Fajar SusantoAfiliasi tidak diketahui1
Muhammad Wifaqurrokhman AbdissalamAfiliasi tidak diketahui1
Ari Dwi Nur Indriawan MusyonoAfiliasi tidak diketahui1
Muhamad Reza Wahyu PrasetyoAfiliasi tidak diketahui1
Tegar Oki PrasdikaAfiliasi tidak diketahui1
Imam Fitrah HadiAfiliasi tidak diketahui1
Prastiyo prasAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/JPTM/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 5 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">THREE-DIMENSIONAL FEA OF FIXTURE DIAMETER INFLUENCE ON ABUTMENT AND SCREW IN ANTERIOR MAXILLA BRIDGES</dc:title>
	<dc:creator xml:lang="en">Beni Aji Subekti</dc:creator>
	<dc:creator xml:lang="en">Kriswanto</dc:creator>
	<dc:creator xml:lang="en">Febri Budi Darsono</dc:creator>
	<dc:creator xml:lang="en">Rahmat Doni Widodo</dc:creator>
	<dc:creator xml:lang="en">J. Jamari</dc:creator>
	<dc:creator xml:lang="en">Athanasius Priharyoto Bayuseno</dc:creator>
	<dc:subject xml:lang="en">FEM, implant diameter, abutment, screw</dc:subject>
	<dc:description xml:lang="en">Numerical simulation-based biomechanical evaluation was used to analyze the effect of implant diameter variation on stress and strain on the abutment and screw using the Finite Element Method (FEM). Modeling was performed based on CBCT data and simulated in ANSYS Workbench 2023 R1. Three implant diameters were tested (3.75 mm, 4.3 mm, and 5.0 mm), each subjected to a force of 204.1 N at a 45° angle to mimic anterior functional conditions. The 4.3 mm diameter produced the highest stress on the abutment (213.62 MPa), while the 5.0 mm diameter showed the lowest stress (192.5 MPa) and minimum strain (0.00178). The 5.0 mm diameter also reduced the load on the screw, indicating a more stable load distribution. Therefore, this diameter is recommended as the optimal biomechanical configuration for anterior implant bridges, while considering anatomical limitations.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/JPTM/article/view/29860</dc:identifier>
	<dc:identifier>10.15294/jptm.v26i01.29860</dc:identifier>
	<dc:source xml:lang="en">Jurnal Pendidikan Teknik Mesin; Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"; 45 - 55</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>10.15294/jptm.v26i01</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/JPTM/article/view/29860/11031</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Pendidikan Teknik Mesin</dc:rights>
</oai_dc:dc>