Melola Discovery

← Melola Discovery

Jurnal

COMPARATIVE BIOMECHANICAL ANALYSIS OF POSTERIOR MANDIBULAR PREMOLAR IMPLANTS: EFFECTS OF MATERIAL MODELING, CONTACT CONDITIONS, AND LOADING DIRECTION

Jurnal Pendidikan Teknik Mesin · Vol. 26 No. 01 (2026) · hlm. 80–96

DOI
10.15294/jptm.v26i01.54363
ISSN
2503-1759, 2503-1759
Terbit
2026-08-10
Penerbit
Universitas Negeri Semarang
Bahasa
eng

Abstrak

Posterior tooth loss in the mandibular region may reduce masticatory performance and compromise biomechanical stability, thereby requiring predictable and well-designed implant rehabilitation strategies. This study evaluates the mechanical behavior of an implant–bone system by considering variations in bone material representation (isotropic and orthotropic models), implant–bone interface conditions (fully bonded and frictional contact), and loading orientations (axial and oblique) through a validated three-dimensional finite element analysis (3D-FEA) framework. A full factorial design comprising eight simulation configurations was implemented to assess 15 biomechanical output parameters, including von Mises stress, principal strain, and displacement across implant components and surrounding cortical and cancellous bone tissues. The results indicate that the biomechanical response of the system is strongly dependent on both structural components and loading context. The orthotropic bone model tends to increase stress and deformation responses under specific conditions, whereas oblique loading generally produces higher peak mechanical responses than axial loading. Furthermore, the influence of contact conditions is not uniform but varies according to material assumptions and loading direction, suggesting that simplified fully bonded interfaces may not fully capture realistic implant–bone interactions. Overall, the findings highlight the importance of incorporating anisotropic bone behavior, realistic interface modeling, and clinically relevant loading directions to improve the accuracy of stress prediction around dental implants. This study provides numerical evidence that may support improved implant design strategies and enhance the reliability of future finite element–based biomechanical investigations.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 174 tautan kepenulisan bersama · 74 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Diponegoro University
  • Universiti Malaysia Sarawak
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rahmat Doni WidodoState University of Semarang8
J. JamariDiponegoro University8
Ruben Bayu KristiawanState University of Semarang8
KriswantoAfiliasi tidak diketahui5
Fatkhu AmanullohState University of Semarang5
Dzikra Adi PratamaState University of Semarang5
Febri Budi DarsonoState University of Semarang4
Alifian Bagas SaputraState University of Semarang4
Septian Eko CahyonoState University of Semarang4
Hastaka Juan Pratama PutraState University of Semarang4
Deni Fajar FitriyanaState University of Semarang3
Gunagung syahrul nizam sulkanState University of Semarang3
Januar Parlaungan SiregarUniversiti Malaysia Pahang Al-Sultan Abdullah2
J. JamariDiponegoro University2
Rachael AndikaState University of Semarang2
Beni Aji SubektiState University of Semarang2
Muhammad Iqbal RamadhaniState University of Semarang2
Khoirudin FathoniState University of Semarang1
Atta Putra HarjantoState University of Semarang1
AbdurrahmanState University of Semarang1
MUHAMMAD NUR FAIZINState University of Semarang1
R. Imanu Danar HerunandiState University of Semarang1
R. Ambar Kuntoro Mursit GendroyonoState University of Semarang1
Nugroho Fajar SusantoState University of Semarang1
Fadhil Putra RamadhanState University of Semarang1
Kaleb PriyantoState University of Semarang1
Septian Eko CahyantoState University of Semarang1
Andrean Rachman RizaldyState University of Semarang1
Agus PrasetyoDiponegoro University1
Risky IsmailAfiliasi tidak diketahui1
Samsudin AnisState University of Semarang1
Muhammad AfrizalDiponegoro University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/JPTM/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">COMPARATIVE BIOMECHANICAL ANALYSIS OF POSTERIOR MANDIBULAR PREMOLAR IMPLANTS: EFFECTS OF MATERIAL MODELING, CONTACT CONDITIONS, AND LOADING DIRECTION</dc:title>
	<dc:creator xml:lang="en">Dennis Andhara Putra</dc:creator>
	<dc:creator xml:lang="en">Kriswanto</dc:creator>
	<dc:creator xml:lang="en">Khoirul Huda </dc:creator>
	<dc:creator xml:lang="en">Jamari</dc:creator>
	<dc:creator xml:lang="en">Athanasius Priharyoto Bayuseno</dc:creator>
	<dc:creator xml:lang="en">Dhiaulhaque</dc:creator>
	<dc:creator xml:lang="en">Nurul Fatulloh</dc:creator>
	<dc:creator xml:lang="en">Syahmi Jamaludin, Mohd</dc:creator>
	<dc:subject xml:lang="en"> implant biomechanical response</dc:subject>
	<dc:subject xml:lang="en"> bone–implant mechanical behavior</dc:subject>
	<dc:subject xml:lang="en"> computational implant modeling</dc:subject>
	<dc:subject xml:lang="en">orthotropic bone model</dc:subject>
	<dc:subject xml:lang="en"> loading direction</dc:subject>
	<dc:description xml:lang="en">Posterior tooth loss in the mandibular region may reduce masticatory performance and compromise biomechanical stability, thereby requiring predictable and well-designed implant rehabilitation strategies. This study evaluates the mechanical behavior of an implant–bone system by considering variations in bone material representation (isotropic and orthotropic models), implant–bone interface conditions (fully bonded and frictional contact), and loading orientations (axial and oblique) through a validated three-dimensional finite element analysis (3D-FEA) framework. A full factorial design comprising eight simulation configurations was implemented to assess 15 biomechanical output parameters, including von Mises stress, principal strain, and displacement across implant components and surrounding cortical and cancellous bone tissues. The results indicate that the biomechanical response of the system is strongly dependent on both structural components and loading context. The orthotropic bone model tends to increase stress and deformation responses under specific conditions, whereas oblique loading generally produces higher peak mechanical responses than axial loading. Furthermore, the influence of contact conditions is not uniform but varies according to material assumptions and loading direction, suggesting that simplified fully bonded interfaces may not fully capture realistic implant–bone interactions. Overall, the findings highlight the importance of incorporating anisotropic bone behavior, realistic interface modeling, and clinically relevant loading directions to improve the accuracy of stress prediction around dental implants. This study provides numerical evidence that may support improved implant design strategies and enhance the reliability of future finite element–based biomechanical investigations. </dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/JPTM/article/view/54363</dc:identifier>
	<dc:identifier>10.15294/jptm.v26i01.54363</dc:identifier>
	<dc:source xml:lang="en">Jurnal Pendidikan Teknik Mesin; Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"; 80 - 96</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>2503-1759</dc:source>
	<dc:source>10.15294/jptm.v26i01</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/JPTM/article/view/54363/11034</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Pendidikan Teknik Mesin</dc:rights>
</oai_dc:dc>