Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Low Power CMOS Electrocardiogram Amplifier Design for Wearable Cardiac Screening

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 3 (2018)

DOI
10.11591/ijece.v8i3.pp1830-1836
ISSN
2088-8708, 2088-8708
Terbit
2018-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

The trend of health care screening devices in the world is increasingly towards the favor of portability and wearability. This is because these wearable screening devices are not restricting the patient’s freedom and daily activities. While the demand of low power and low cost biomedical system on chip is increasing in exponential way, the front-end electrocardiogram (ECG) amplifiers are still suffering from flicker noise for low frequency cardiac signal acquisition, 50Hz power line electromagnetic interference, and the large unstable input offsets due to the electrode-skin interface is not attached properly. In this paper, a CMOS based ECG amplifier that suitable for low power wearable cardiac screening is proposed. The amplifier adopts the highly stable folded cascode topology and later being implemented into RC feedback circuit for low frequency DC offset cancellation. By using 0.13µm CMOS technology from Silterra, the simulation results show that this front-end circuit can achieve a very low input referred noise of 1pV/Hz1/2 and high common mode rejection ratio of 174.05dB. It also gives voltage gain of 75.45dB with good power supply rejection ratio of 92.12dB. The total power consumption is only 3µW and thus suitable to be implemented with further signal processing and classification back end for low power wearable biomedical device.

Jaringan kolaborasi para penulis

5 penulis · 8 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Kementerian Pendidikan Malaysia
  • Tun Hussein Onn University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Marriatyi MorsinKementerian Pendidikan Malaysia3
Marlia MorsinTun Hussein Onn University of Malaysia2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Low Power CMOS Electrocardiogram Amplifier Design for Wearable Cardiac Screening</dc:title><dc:creator>Weng, Ow Tze</dc:creator><dc:creator>Isaak, Suhaila</dc:creator><dc:creator>Yusof, Yusmeeraz</dc:creator><dc:description>&lt;jats:p&gt;The trend of health care screening devices in the world is increasingly towards the favor of portability and wearability. This is because these wearable screening devices are not restricting the patient’s freedom and daily activities. While the demand of low power and low cost biomedical system on chip is increasing in exponential way, the front-end electrocardiogram (ECG) amplifiers are still suffering from flicker noise for low frequency cardiac signal acquisition, 50Hz power line electromagnetic interference, and the large unstable input offsets due to the electrode-skin interface is not attached properly. In this paper, a CMOS based ECG amplifier that suitable for low power wearable cardiac screening is proposed. The amplifier adopts the highly stable folded cascode topology and later being implemented into RC feedback circuit for low frequency DC offset cancellation. By using  0.13µm CMOS technology from Silterra, the simulation results show that this front-end circuit can achieve a very low input referred noise of  1pV/Hz1/2 and high common mode rejection ratio of 174.05dB. It also gives voltage gain of 75.45dB with good power supply rejection ratio of 92.12dB. The total power consumption is only 3µW and thus suitable to be implemented with further signal processing and classification back end for low power wearable biomedical device.&amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i3.pp1830-1836</dc:identifier><dc:identifier>10.11591/ijece.v8i3.pp1830-1836</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 3 (2018); 1830</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/11789/8723</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>