Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Dynamic Voltage Stability Comparison of Thermal and Wind Power Generation with Different Static and Dynamic Load Models

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 3 (2018)

DOI
10.11591/ijece.v8i3.pp1401-1411
ISSN
2088-8708, 2088-8708
Published
2018-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper presents a static and dynamic voltage stability analysis of a power network with thermal and wind generation considering static and dynamic load models. The thermal plant was modeled as a synchronous machine and the wind farm as a variable speed induction generator based on a doubly-fed induction generator. The load considered the ZIP, exponential recovery, induction motor, and frequency-dependent load models. The bifurcation points were found by continuation power flow and sensitivity analyses. In addition, dynamic voltage stability assessments were performed considering changes in the moment of inertia and the frequency parameters. All simulations were carried out in a 4-bus power system and using the power system analysis toolbox (PSAT) and MATLAB script code. The results show that the thermal generator had difficulties to maintain stability under dynamic load variations and frequency changes, the wind generator had difficulties to maintain voltage for the load with induction motors, and both generators had difficulties when the moment of inertia is increased.

Collaboration network of the authors

13 authors · 21 co-authorship links · 9 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad Nacional de Colombia
  • Universidad del Magdalena
  • Universidad de la Costa
  • Institución Universitaria Pascual Bravo
  • National Research Council
  • Tecnológico de Antioquia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Fredy E. HoyosUniversidad Nacional de Colombia7
John Alexander TabordaUniversidad del Magdalena1
Michel Duran-QuinteroUniversidad de la Costa1
Jose Soto-OrtizAffiliation unknown1
Héctor A. Tabares-OspinaInstitución Universitaria Pascual Bravo1
Mauricio García VargasUniversidad Nacional de Colombia1
Carlos Ildefonso Hoyos VelascoNational Research Council1
Luis Gabriel Lafaurie PonceUniversidad Nacional de Colombia1
Sergio Andrés Pizarro PérezAffiliation unknown1
Eder Alexander Molina ViloriaTecnológico de Antioquia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Dynamic Voltage Stability Comparison of Thermal and Wind Power Generation with Different Static and Dynamic Load Models</dc:title><dc:creator>Acevedo, Lina F.</dc:creator><dc:creator>Bothia-Vargas, Gilbert</dc:creator><dc:creator>Candelo, John Edwin</dc:creator><dc:description>&lt;jats:p&gt;This paper presents a static and dynamic voltage stability analysis of a power network with thermal and wind generation considering static and dynamic load models. The thermal plant was modeled as a synchronous machine and the wind farm as a variable speed induction generator based on a doubly-fed induction generator. The load considered the ZIP, exponential recovery, induction motor, and frequency-dependent load models. The bifurcation points were found by continuation power flow and sensitivity analyses. In addition, dynamic voltage stability assessments were performed considering changes in the moment of inertia and the frequency parameters. All simulations were carried out in a 4-bus power system and using the power system analysis toolbox (PSAT) and MATLAB script code. The results show that the thermal generator had difficulties to maintain stability under dynamic load variations and frequency changes, the wind generator had difficulties to maintain voltage for the load with induction motors, and both generators had difficulties when the moment of inertia is increased.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i3.pp1401-1411</dc:identifier><dc:identifier>10.11591/ijece.v8i3.pp1401-1411</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 3 (2018); 1401</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/9655/8681</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>