Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

A Novel Study on Bipolar High Voltage Direct Current Transmission Lines Protection Schemes

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 4 (2018)

DOI
10.11591/ijece.v8i4.pp1977-1984
ISSN
2088-8708, 2088-8708
Published
2018-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

In long dc transmission lines identification of fault is important for transferring a large amount of power. In bipolar Line commutated converter transmission lines are subjected to harsh weather condition so accurate and rapid clearance of fault is essential. A comparative study of the bipolar system with both converters healthy and one converter tripped is studied. Most of the research paper has focussed on transmission line faults in bipolar mode but none of them had focussed when HVDC system works in monopolar mode after the fault. In the proposed scheme the voltage signals are extracted from both poles of the rectifier ends and are processed to identify the faults in transmission lines.The Artificial neural network is utilised in detecting the fault in both bipolar and monopolar system. Since it can identify the relationship between input and output data to detect the fault pattern it can be utilised under all conditions. Moreover, benefits of the proposed method are its accuracy, no requirement of the communication system as it acquires data from one end and has a reach setting of 99%.

Collaboration network of the authors

4 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • KIIT University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A Novel Study on Bipolar High Voltage Direct Current Transmission Lines Protection Schemes</dc:title><dc:creator>Agarwal, Shobha</dc:creator><dc:creator>Panigrahi, C. K.</dc:creator><dc:creator>Sahoo, Aishwarya</dc:creator><dc:creator>Mishra, Sanitha</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;&amp;lt;span&amp;gt;In long dc transmission lines identification of fault is important for transferring a large amount of power. In bipolar &amp;lt;/span&amp;gt;&amp;lt;span lang="EN-GB"&amp;gt;Line commutated converter transmission lines &amp;lt;/span&amp;gt;&amp;lt;span&amp;gt;are subjected to harsh weather condition so accurate and rapid clearance of fault is essential. A comparative study of the bipolar system with both converters healthy and one converter tripped is studied. Most of the research paper has focussed on transmission line faults in bipolar mode but none of them had focussed when HVDC system works in monopolar mode after the fault. In the proposed scheme the voltage signals are extracted from both poles of the rectifier ends and are processed to identify the faults in transmission lines.The Artificial neural network is utilised in detecting the fault in both bipolar and monopolar system. Since it can identify the relationship between input and output data to detect the fault pattern it can be utilised under all conditions. Moreover, benefits of the proposed method are its accuracy, no requirement of the communication system as it acquires data from one end and has a reach setting of 99%.&amp;lt;/span&amp;gt;&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i4.pp1977-1984</dc:identifier><dc:identifier>10.11591/ijece.v8i4.pp1977-1984</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 4 (2018); 1977</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8072/8834</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>