Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance Evaluation of Two Port and Four Port Measurement for Twisted Pair Cable

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 4 (2018)

DOI
10.11591/ijece.v8i4.pp2624-2632
ISSN
2088-8708, 2088-8708
Terbit
2018-08-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

A balance-unbalance (balun) transformer is commonly used to connect the balance 100 Ohm twisted pair cable to the unbalance 50 Ohm network analyzer ports, but due to the limitations of the core (i.e. ferrite) inside the balun, the balun can only effectively operates at a certain band of frequencies. This limitation can be eliminated by using a 4-port vector network analyzer (VNA) which is done by connecting the VNA’s ports to each conductor end. The extracted S-parameters will then be transformed to a 2-port S-parameters in differential mode at both ports. To validate the measurement technique, S-parameter measurement by using the 4-Port Network Analyzer without any balun will be compared to the measurement which used the 2-Port Network Analyzer with the balun transformers. Two twisted pair cable distances are selected as reference which are 500, and 1000 meters with nominal copper diameter of 0.5mm. Based on the measurement results, the 4-ports measurement shows good correlation with the 2-ports measurement especially at 500m distance. This shows that the 4-ports measurement setup is suitable to be used to measure twisted pair copper cable and possible to measure at a higher frequency band such as up to 500 MHz but at a shorter twisted pair cable distance.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Performance Evaluation of Two Port and Four Port Measurement for Twisted Pair Cable</dc:title><dc:creator>Bin Asrokin, Azhari</dc:creator><dc:creator>Bin A. Rahim, Mohamad Kamal</dc:creator><dc:description>&lt;jats:p&gt;A balance-unbalance (balun) transformer is commonly used to connect the balance 100 Ohm twisted pair cable to the unbalance 50 Ohm network analyzer ports, but due to the limitations of the core (i.e. ferrite) inside the balun, the balun can only effectively operates at a certain band of frequencies. This limitation can be eliminated by using a 4-port vector network analyzer (VNA) which is done by connecting the VNA’s ports to each conductor end. The extracted S-parameters will then be transformed to a 2-port S-parameters in differential mode at both ports. To validate the measurement technique, S-parameter measurement by using the 4-Port Network Analyzer without any balun will be compared to the measurement which used the 2-Port Network Analyzer with the balun transformers. Two twisted pair cable distances are selected as reference which are 500, and 1000 meters with nominal copper diameter of 0.5mm. Based on the measurement results, the 4-ports measurement shows good correlation with the 2-ports measurement especially at 500m distance. This shows that the 4-ports measurement setup is suitable to be used to measure twisted pair copper cable and possible to measure at a higher frequency band such as up to 500 MHz but at a shorter twisted pair cable distance.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i4.pp2624-2632</dc:identifier><dc:identifier>10.11591/ijece.v8i4.pp2624-2632</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 4 (2018); 2624</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/11906/9110</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>