Hysteresis-based Voltage and Current Control Techniques for Grid Connected Solar Photovoltaic Systems: Comparative Study

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 5 (2018)

DOI
10.11591/ijece.v8i5.pp2671-2681
ISSN
2088-8708, 2088-8708
Published
2018-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Solar PV system development and integration with existing grid is very fast in recent years all over the world, as they require limited maintenance, pollution free and simple structure. When observing the factors affecting the performance of the grid connected solar photovoltaic system, the inverter output voltage with harmonics add with the harmonics generated due to the non-linear loads, retain a bigger challenge to maintain power quality in the grid. To maintain grid power quality, better inverter control technique should be developed. This paper presents the two control techniques for grid-tied inverters. This study developed the hysteresis controller for the inverter. Hysteresis controller used in this work two way (i) Voltage control mode (ii) Current control mode. Matlab/Simulink model is developed for the proposed system. Further the study presents the comparative evaluation of the performance of both control techniques based on the percentage of total harmonic distortion (THD) with the limits specified by the standards such as IEEE 1547 and IEC 61727 and IEEE Std 519-2014

Collaboration network of the authors

4 authors · 5 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Kalasalingam Academy of Research and Education
  • King Faisal University
  • Visvesvaraya Technological University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
S. N. RekhaVisvesvaraya Technological University2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Hysteresis-based Voltage and Current Control Techniques for Grid Connected Solar Photovoltaic Systems: Comparative Study</dc:title><dc:creator>Raja Mohamed, S.</dc:creator><dc:creator>Jeyanthy, P. Aruna</dc:creator><dc:creator>Devaraj, D.</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Solar PV system development and integration with existing grid is very fast in recent years all over the world, as they require limited maintenance, pollution free and simple structure. When observing the factors affecting the performance of the grid connected solar photovoltaic system, the inverter output voltage with harmonics add with the harmonics generated due to the non-linear loads, retain a bigger challenge to maintain power quality in the grid. To maintain grid power quality, better inverter control technique should be developed. This paper presents the two control techniques for grid-tied inverters. This study developed the hysteresis controller for the inverter. Hysteresis controller used in this work two way (i) Voltage control mode (ii) Current control mode. Matlab/Simulink model is developed for the proposed system. Further the study presents the comparative evaluation of the performance of both control techniques based on the percentage of total harmonic distortion (THD) with the limits specified by the standards such as IEEE 1547 and IEC 61727 and IEEE Std 519-2014&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i5.pp2671-2681</dc:identifier><dc:identifier>10.11591/ijece.v8i5.pp2671-2681</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 5 (2018); 2671</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8989/10941</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>