Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Improved p-q Harmonic Detection Method for Hybrid Active Power Filter

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 5 (2018)

DOI
10.11591/ijece.v8i5.pp2910-2919
ISSN
2088-8708, 2088-8708
Published
2018-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

The accuratedetermination of the load harmonic current is one of the important factors, it decides to effect of harmonic filtering and reactive power compensation for Hybrid Active Power Filter. The p-q harmonic detection method has been widely used in determining the harmonic currents of Hybrid Active Power Filter. However, when using this method, the dynamic response of Hybrid Active Power Filter in the transient period will have a large transient time and overshoot whenever the load changes abruptly. Therefore, in this paper an improved p-q harmonic current detection method based on fuzzy logic is proposed, which aims to reduce the overshoot and transient time in transient duration of Hybrid Active Power Filter. In order to compare the dynamic response of conventional and improved p-q harmonic detection methods, simulation results have demonstrated that: the proposed method has a shorter response time, the magnitude of the supply current in the transient time is smaller and the overshoot of the fundamental active and reactive power components is very small. This has a practical significance that contributes to the stability of the Hybrid Active Power Filter system

Collaboration network of the authors

5 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Industrial University of Ho Chi Minh City
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hoài Thương NguyễnIndustrial University of Ho Chi Minh City2
Truong Khac TungIndustrial University of Ho Chi Minh City1
Phan Thi Bich ThaoIndustrial University of Ho Chi Minh City1
Le Quang BinhIndustrial University of Ho Chi Minh City1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Improved p-q Harmonic Detection Method for Hybrid Active Power Filter</dc:title><dc:creator>Thuyen, Chau Minh</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;The accuratedetermination of the load harmonic current is one of the important factors, it decides to effect of harmonic filtering and reactive power compensation for Hybrid Active Power Filter. The p-q harmonic detection method has been widely used in determining the harmonic currents of Hybrid Active Power Filter. However, when using this method, the dynamic response of Hybrid Active Power Filter in the transient period will have a large transient time and overshoot whenever the load changes abruptly. Therefore, in this paper an improved p-q harmonic current detection method based on fuzzy logic is proposed, which aims to reduce the overshoot and transient time in transient duration of Hybrid Active Power Filter. In order to compare the dynamic response of conventional and improved p-q harmonic detection methods, simulation results have demonstrated that: the proposed method has a shorter response time, the magnitude of the supply current in the transient time is smaller and the overshoot of the fundamental active and reactive power components is very small. This has a practical significance that contributes to the stability of the Hybrid Active Power Filter system&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i5.pp2910-2919</dc:identifier><dc:identifier>10.11591/ijece.v8i5.pp2910-2919</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 5 (2018); 2910</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7800/10976</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>