Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Intelligent Sensing Using Metal Oxide Semiconductor Based-on Support Vector Machine for Odor Classification

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 6 (2018)

DOI
10.11591/ijece.v8i6.pp4133-4147
ISSN
2088-8708, 2088-8708
Published
2018-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Classifying odor in real experiment presents some challenges, especially the uncertainty of the odor concentration and dispersion that can lead to a difficulty in obtaining an accurate datasets. In this study, to enhance the accuracy, datasets arrangement based on MOS sensors parameters using SVM approach for odor classification is proposed. The sensors are tested to determine the sensors' time response, sensors' peak duration, sensors' sensitivity, and sensors' stability when applied to the various sources at different range. Three sources were used in experimental test, namely: ethanol, methanol, and acetone. The gas sensors characteristics are analyzed in open sampling method to see the sensors' performance in real situation. These performances are considered as the base of choosing the position in collecting the datasets. The sensors in dynamic experiment have average of precision of 93.8-97.0%, the accuracy 93.3-96.7%, and the recall 93.3-96.7%. This values indicates that the collected datasets can support the SVM in improving the intelligent sensing when conducting odor classification work.

Collaboration network of the authors

17 authors · 61 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Sriwijaya University
  • Politeknik Negeri Sriwijaya
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Bambang TutukoSriwijaya University3
Ade Iriani SapitriSriwijaya University2
Muhammad Naufal RachmatullahSriwijaya University2
Annisa DarmawahyuniSriwijaya University2
Firdaus FirdausSriwijaya University2
Anggun IslamiSriwijaya University2
Akhiar Wista ArumSriwijaya University2
Tresna DewiPoliteknik Negeri Sriwijaya1
Pola RismaPoliteknik Negeri Sriwijaya1
Yurni OktarinaPoliteknik Negeri Sriwijaya1
Muhammad RorizPoliteknik Negeri Sriwijaya1
Ghita AthalinaAffiliation unknown1
Muhammad Alpim Alfa RolisAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Intelligent Sensing Using Metal Oxide Semiconductor Based-on Support Vector Machine for Odor Classification</dc:title><dc:creator>Husni, Nyayu Latifah</dc:creator><dc:creator>Nurmaini, Siti</dc:creator><dc:creator>Yani, Irsyadi</dc:creator><dc:creator>Silvia, Ade</dc:creator><dc:description>&lt;jats:p&gt;Classifying odor in real experiment presents some challenges, especially the uncertainty of the odor concentration and dispersion that can lead to a difficulty in obtaining an accurate datasets. In this study, to enhance the accuracy, datasets arrangement based on MOS sensors parameters using SVM approach for odor classification is proposed. The sensors are tested to determine the sensors' time response, sensors' peak duration, sensors' sensitivity, and sensors' stability when applied to the various sources at different range. Three sources were used in experimental test, namely: ethanol, methanol, and acetone. The gas sensors characteristics are analyzed in open sampling method to see the sensors' performance in real situation. These performances are considered as the base of choosing the position in collecting the datasets. The sensors in dynamic experiment have average of precision of 93.8-97.0%, the accuracy 93.3-96.7%, and the recall 93.3-96.7%. This values indicates that the collected datasets can support the SVM in improving the intelligent sensing when conducting odor classification work.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i6.pp4133-4147</dc:identifier><dc:identifier>10.11591/ijece.v8i6.pp4133-4147</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 6 (2018); 4133</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/9905/11157</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>