Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Implementation and design of new low-cost foot pressure sensor module using piezoelectric sensor in T-FLoW humanoid robot

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 1 (2019)

DOI
10.11591/ijece.v9i1.pp203-214
ISSN
2088-8708, 2088-8708
Published
2019-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Basically, human can sense the active body force trough the soles of their feet and can feel the position vector of zero moment point (ZMP) based on the center of pressure (CoP) from active body force. This behavior is adapted by T-FLoW humanoid robot using unique sensor which is piezoelectric sensor. Piezoelectric sensor has a characteristic which is non-continuous reading (record a data only a moment). Because of it, this sensor cannot be used to stream data such as flex sensor, loadcell sensor, and torque sensor like previous research. Therefore, the piezoelectric sensor still can be used to measure the position vector of ZMP. The idea is using this sensor in a special condition which is during landing condition. By utilizing 6 unit of piezoelectric sensor with a certain placement, the position vector of ZMP (X-Y-axis) and pressure value in Z-axis from action body force can be found. The force resultant method is used to find the position vector of ZMP from each piezoelectric sensor. Based on those final conclusions in each experiment, the implementation of foot pressure sensor modul using piezoelectric sensor has a good result (94%) as shown in final conclusions in each experiment. The advantages of this new foot pressure sensor modul is low-cost design and similar result with another sensor. The disadvantages of this sensor are because of the main characteristic of piezoelectric sensor (non-continuous read) sometimes the calculation has outlayer data.

Collaboration network of the authors

9 authors · 16 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Politeknik Elektronika Negeri Surabaya
  • Politeknik Perkapalan Negeri Surabaya
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Eko Henfri BinugrohoPoliteknik Elektronika Negeri Surabaya1
Muhammad Ramadhan Hadi SetyawanPoliteknik Elektronika Negeri Surabaya1
Raden Sanggar DewantoPoliteknik Elektronika Negeri Surabaya1
Bayu Sandi MartaPoliteknik Elektronika Negeri Surabaya1
Adianto AdiantoPoliteknik Perkapalan Negeri Surabaya1
Annas Singgih SetiyokoPoliteknik Perkapalan Negeri Surabaya1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Implementation and design of new low-cost foot pressure sensor module using piezoelectric sensor in T-FLoW humanoid robot</dc:title><dc:creator>Pristovani, R. Dimas</dc:creator><dc:creator>Sanggar, Dewanto</dc:creator><dc:creator>Dadet, Pramadihanto</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span lang="EN-US"&amp;gt;Basically, human can sense the active body force trough the soles of their feet and can feel the position vector of zero moment point (ZMP) based on the center of pressure (CoP) from active body force. This behavior is adapted by T-FLoW humanoid robot using unique sensor which is piezoelectric sensor. Piezoelectric sensor has a characteristic which is non-continuous reading (record a data only a moment). Because of it, this sensor cannot be used to stream data such as flex sensor, loadcell sensor, and torque sensor like previous research. Therefore, the piezoelectric sensor still can be used to measure the position vector of ZMP. The idea is using this sensor in a special condition which is during landing condition. By utilizing 6 unit of piezoelectric sensor with a certain placement, the position vector of ZMP (X-Y-axis) and pressure value in Z-axis from action body force can be found. The force resultant method is used to find the position vector of ZMP from each piezoelectric sensor. Based on those final conclusions in each experiment, the implementation of foot pressure sensor modul using piezoelectric sensor has a good result (94%) as shown in final conclusions in each experiment. The advantages of this new foot pressure sensor modul is low-cost design and similar result with another sensor. The disadvantages of this sensor are because of the main characteristic of piezoelectric sensor (non-continuous read) sometimes the calculation has outlayer data.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i1.pp203-214</dc:identifier><dc:identifier>10.11591/ijece.v9i1.pp203-214</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 1 (2019); 203</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/13099/11048</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>