Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Karakteristik Hamonik Pada Beban Nonlinear Lampu LED

Edu Elektrika Journal · Vol. 8 No. 2 (2019) · hlm. 60–65

DOI
10.15294/eej.v8i2.38548
ISSN
2723-5602, 2252-7095
Terbit
2019-12-20
Penerbit
Electrical Engineering, Universitas Negeri Semarang
Bahasa
eng

Abstrak

Harmonics is a phenomenon in electric power systems that causes quality problems where the current or voltage waveforms of the supply will become distorted so that it can cause overheating in each magnetic core in the electrical equipment. This enlargement of the harmonics triggers the enlargement of power losses in the core due to the eddy currents it causes. This will reduce the input energy so that the efficiency of the tool decreases. Harmonic distortion of the sinusoidal waveforms of voltage and current needs to be investigated and these harmonics are generally triggered by nonlinear loads, one of which is LED lamp. LED lamps are one of the nonlinear loads that use rectifier components in them. In this research, we have tested the voltage harmonic content, current harmonic, on 3 brands of LED lamps and used the IEEE 519-2014 standard as a reference in setting the maximum harmonic voltage and current limits. Measurements in this study were carried out using the HIOKI 3197 brand Power Quality Analyzer. From the test results showed that the total harmonic distortion (THD) voltage on various brands of LED lamps did not exceed the IEEE 519-2014 standard limit which is a maximum of 5% because the largest harmonic voltage is 2, 9%. While the total harmonic distortion (THD) of current in various brands of LED lamps has the largest THD value of 170.6%.

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/sju/index.php/eduel/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Karakteristik Hamonik Pada Beban Nonlinear Lampu LED</dc:title>
	<dc:creator>Sarwono, Edi</dc:creator>
	<dc:description xml:lang="en-US">Harmonics is a phenomenon in electric power systems that causes quality problems where the current or voltage waveforms of the supply will become distorted so that it can cause overheating in each magnetic core in the electrical equipment. This enlargement of the harmonics triggers the enlargement of power losses in the core due to the eddy currents it causes. This will reduce the input energy so that the efficiency of the tool decreases. Harmonic distortion of the sinusoidal waveforms of voltage and current needs to be investigated and these harmonics are generally triggered by nonlinear loads, one of which is LED lamp. LED lamps are one of the nonlinear loads that use rectifier components in them. In this research, we have tested the voltage harmonic content, current harmonic, on 3 brands of LED lamps and used the IEEE 519-2014 standard as a reference in setting the maximum harmonic voltage and current limits. Measurements in this study were carried out using the HIOKI 3197 brand Power Quality Analyzer. From the test results showed that the total harmonic distortion (THD) voltage on various brands of LED lamps did not exceed the IEEE 519-2014 standard limit which is a maximum of 5% because the largest harmonic voltage is 2, 9%. While the total harmonic distortion (THD) of current in various brands of LED lamps has the largest THD value of 170.6%.</dc:description>
	<dc:publisher xml:lang="en-US">Electrical Engineering, Universitas Negeri Semarang</dc:publisher>
	<dc:date>2019-12-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer Reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/sju/eduel/article/view/38548</dc:identifier>
	<dc:identifier>10.15294/eej.v8i2.38548</dc:identifier>
	<dc:source xml:lang="en-US">Edu Elektrika Journal; Vol 8 No 2 (2019): Edu Elektrika Journal; 60-65</dc:source>
	<dc:source>2723-5602</dc:source>
	<dc:source>2252-7095</dc:source>
	<dc:source>10.15294/eej.v8i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/sju/eduel/article/view/38548/15944</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Edu Elektrika Journal</dc:rights>
</oai_dc:dc>