Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Energy storage of DFIG based wind farm using D-STATCOM

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 2 (2019)

DOI
10.11591/ijece.v9i2.pp761-770
ISSN
2088-8708, 2088-8708
Terbit
2019-04-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

To accommodate the regularity of wind energy; a storage device is required for the wind turbine. This paper proposesa constant power control for wind farm based Doubly Fed Induction Generator, the suggested storage device is supercapacitor which is connected to every wind turbine of the wind farm, it provides output power stability and compensates the deviations between the available wind energy input and the desired active power output. A Distribution – Static Synchronous Compensator (D-STATCOM) is connected at the point of connection of the wind farm, it controls the active and reactive power according to the demand from orpower generation to the electrical grid. The coordinated approach between the supercapacitors and the D-STATCOM mitigates the voltage magnitude fluctuations of the wind farm and provides support to the active power. Simulation studies are carried out inMATLAB/Simulink.

Jaringan kolaborasi para penulis

20 penulis · 36 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Ecole Mohammadia d'Ingénieurs
  • Université Moulay Ismail de Meknes
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anass BakouriMohammed V University2
Marouane El AzzaouiMohammed V University2
Moine El HajjiMohammed V University1
Moussa LabbadiMohammed V University1
Naoufal ZhaniMohammed V University1
Chafik Ed-dahmaniUniversité Moulay Ismail de Meknes1
Sana SahbaniMohammed V University1
Abdennebi El HasnaouiAfiliasi tidak diketahui1
Mustapha KchikachAfiliasi tidak diketahui1
Hanane BenchraaMohammed V University1
Ilham RaisMohammed V University1
Karima BoudaraiaEcole Mohammadia d'Ingénieurs1
Ahmed AbbouMohammed V University1
Abdelaali OuhammamAfiliasi tidak diketahui1
Youssef El HachimiAfiliasi tidak diketahui1
Amina DaghouriAfiliasi tidak diketahui1
Abdennebi El HassnaouiAfiliasi tidak diketahui1
Nabil QachchachiEcole Mohammadia d'Ingénieurs1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Energy storage of DFIG based wind farm using D-STATCOM</dc:title><dc:creator>Rabyi, Kaoutar</dc:creator><dc:creator>Mahmoudi, Hassane</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;To accommodate the regularity of wind energy; a storage device is required for the wind turbine. This paper proposesa constant power control for wind farm based Doubly Fed Induction Generator, the suggested storage device is supercapacitor which is connected to every wind turbine of the wind farm, it provides output power stability and compensates the deviations between the available wind energy input and the desired active power output. A Distribution – Static Synchronous Compensator (D-STATCOM) is connected at the point of connection of the wind farm, it controls the active and reactive power according to the demand from orpower generation to the electrical grid. The coordinated approach between the supercapacitors and the D-STATCOM mitigates the voltage magnitude fluctuations of the wind farm and provides support to the active power. Simulation studies are carried out inMATLAB/Simulink.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i2.pp761-770</dc:identifier><dc:identifier>10.11591/ijece.v9i2.pp761-770</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 2 (2019); 761</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/10690/11576</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>