Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Matlab/simulink simulation of unified power quality conditioner-battery energy storage system supplied by PV-wind hybrid using fuzzy logic controller

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 3 (2019)

DOI
10.11591/ijece.v9i3.pp1479-1495
ISSN
2088-8708, 2088-8708
Published
2019-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper presents performance analysis of Unified Power Quality Conditioner-Battery Energy Storage (UPQC-BES) system supplied by Photovoltaic (PV)-Wind Hybrid connected to three phase three wire (3P3W) of 380 volt (L-L) and 50 hertz distribution system. The performance of supply system is compared with two renewable energy (RE) sources i.e. PV and Wind, respectively. Fuzzy Logic Controller (FLC) is implemented to maintain DC voltage across the capacitor under disturbance scenarios of source and load as well as to compare the results with Proportional Intergral (PI) controller. There are six scenarios of disturbance i.e. (1) non-linear load (NL), (2) unbalance and nonlinear load (Unba-NL), (3) distortion supply and non-linear load (Dis-NL), (4) sag and non-linear load (Sag-NL), (5) swell and non-linear load (Swell-NL), and (6) interruption and non-linear load (Inter-NL). In disturbance scenario 1 to 5, implementation of FLC on UPQC-BES system supplied by three RE sources is able to obtain average THD of load voltage/source current slightly better than PI. Furthermore under scenario 6, FLC applied on UPQC-BES system supplied by three RE sources gives significantly better result of average THD of load voltage/source current than PI. This research is simulated using Matlab/Simulink.

Collaboration network of the authors

29 authors · 74 co-authorship links · 26 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Sepuluh Nopember
  • Universitas Bhayangkara Surabaya
  • Politeknik Negeri Ujung Pandang
  • Politeknik Bosowa
  • State University of Makassar
  • Institut Teknologi Telkom Surabaya
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Suyanto SuyantoInstitut Teknologi Sepuluh Nopember4
Citra RahmadhaniInstitut Teknologi Sepuluh Nopember4
Agus KiswantonoUniversitas Bhayangkara Surabaya3
Rony Seto WibowoInstitut Teknologi Sepuluh Nopember2
Muhira Dzar FarabyPoliteknik Negeri Ujung Pandang2
Ni Ketut AryaniInstitut Teknologi Sepuluh Nopember2
Hudan StudiawanInstitut Teknologi Sepuluh Nopember1
Royyana Muslim IjtihadieInstitut Teknologi Sepuluh Nopember1
I Made Yulistya NegaraInstitut Teknologi Sepuluh Nopember1
Mat Syai’inInstitut Teknologi Sepuluh Nopember1
Adiananda AdianandaUniversitas Bhayangkara Surabaya1
Suhartono SuhartonoInstitut Teknologi Sepuluh Nopember1
Ismit MadoInstitut Teknologi Sepuluh Nopember1
Andi FitriatiPoliteknik Bosowa1
Muhammad Daffa CahyonoputraInstitut Teknologi Sepuluh Nopember1
Dimas Fajar Uman PutraInstitut Teknologi Sepuluh Nopember1
Sofyan SofyanPoliteknik Negeri Ujung Pandang1
Akhyar MuchtarState University of Makassar1
Rezi DelfiantiInstitut Teknologi Sepuluh Nopember1
Bima MustaqimInstitut Teknologi Sepuluh Nopember1
Fauzan NusyuraInstitut Teknologi Telkom Surabaya1
Ardyono PriyadiInstitut Teknologi Sepuluh Nopember1
Imam AbadiInstitut Teknologi Sepuluh Nopember1
Mario Dwi PrasetyoInstitut Teknologi Sepuluh Nopember1
Marcel Nicky AriantoInstitut Teknologi Sepuluh Nopember1
Aulia Amjad LutfiInstitut Teknologi Sepuluh Nopember1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Matlab/simulink simulation of unified power quality conditioner-battery energy storage system supplied by PV-wind hybrid using fuzzy logic controller</dc:title><dc:creator>Amirullah, Amirullah</dc:creator><dc:creator>Penangsang, Ontoseno</dc:creator><dc:creator>Soeprijanto, Adi</dc:creator><dc:description>&lt;jats:p&gt;This paper presents performance analysis of Unified Power Quality Conditioner-Battery Energy Storage (UPQC-BES) system supplied by Photovoltaic (PV)-Wind Hybrid connected to three phase three wire (3P3W) of 380 volt (L-L) and 50 hertz distribution system. The performance of supply system is compared with two renewable energy (RE) sources i.e. PV and Wind, respectively. Fuzzy Logic Controller (FLC) is implemented to maintain DC voltage across the capacitor under disturbance scenarios of source and load as well as to compare the results with Proportional Intergral (PI) controller. There are six scenarios of disturbance i.e. (1) non-linear load (NL), (2) unbalance and nonlinear load (Unba-NL), (3) distortion supply and non-linear load (Dis-NL), (4) sag and non-linear load (Sag-NL), (5) swell and non-linear load (Swell-NL), and (6) interruption and non-linear load (Inter-NL). In disturbance scenario 1 to 5, implementation of FLC on UPQC-BES system supplied by three RE sources is able to obtain average THD of load voltage/source current slightly better than PI. Furthermore under scenario 6, FLC applied on UPQC-BES system supplied by three RE sources gives significantly better result of average THD of load voltage/source current than PI. This research is simulated using Matlab/Simulink.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i3.pp1479-1495</dc:identifier><dc:identifier>10.11591/ijece.v9i3.pp1479-1495</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 3 (2019); 1479</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/13075/12302</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>