Abstract

Electrical energy consumption is one of the focus areas in Green and Sustainable technology in the 21st century. Many energy consultants offers services to reduce the electricity consumption to the commercial consumer. Many proposals are focusing on selling their energy management system product which cost a lot of initial investment. The problem of applying energy management system is that the building needs major renovation. In this paper, electricity consumption is reduced through delamping method. The delamping is strategizing based on energy efficiency audit. This technique complies with the ASHRAE international standard for office building. The number of light reduced and electricity consumption from this exercise can translate into reduction of maintenance and electricity bill. The comparison of payback period for various energy saving techniques were discussed as well.

Collaboration network of the authors

23 authors · 80 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Tun Hussein Onn University of Malaysia
  • Universiti Malaysia Perlis
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Amar Faiz Zainal AbidinUniversiti Teknikal Malaysia Melaka4
Mohd Badril Nor ShahUniversiti Teknikal Malaysia Melaka4
N. A. A. HadiUniversiti Teknikal Malaysia Melaka2
Lim Hui YeeUniversiti Teknikal Malaysia Melaka2
Zulhilmi bin ZaidUniversiti Teknikal Malaysia Melaka2
Z. A. GhaniUniversiti Teknikal Malaysia Melaka2
Norfahaniza ZailanyUniversiti Teknikal Malaysia Melaka2
Arman Hadi AzaharUniversiti Teknikal Malaysia Melaka2
Muhamad Haniff HarunUniversiti Teknikal Malaysia Melaka2
Muhammad Faizal YaakubAffiliation unknown2
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka1
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka1
Weihown TeeAffiliation unknown1
Raja Nor Firdaus Kashfi Raja OthmanUniversiti Teknikal Malaysia Melaka1
Erwan SulaimanAffiliation unknown1
Mahyuzie JenalTun Hussein Onn University of Malaysia1
Syed Muhammad Naufal Syed OthmanTun Hussein Onn University of Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>An analysis of energy saving through delamping method</dc:title><dc:creator>Ab Halim, Mohd Firdaus Mohd</dc:creator><dc:creator>Yaakub, Muhamad Faizal</dc:creator><dc:creator>Harun, Mohamad Haniff</dc:creator><dc:creator>Annuar, Khalil Azha Mohd</dc:creator><dc:creator>Basar, Farriz Hj Md</dc:creator><dc:creator>Omar, Mohd Nazri</dc:creator><dc:description>&lt;jats:p&gt;Electrical energy consumption is one of the focus areas in Green and Sustainable technology in the 21st century. Many energy consultants offers services to reduce the electricity consumption to the commercial consumer. Many proposals are focusing on selling their energy management system product which cost a lot of initial investment. The problem of applying energy management system is that the building needs major renovation. In this paper, electricity consumption is reduced through delamping method. The delamping is strategizing based on energy efficiency audit. This technique complies with the ASHRAE international standard for office building. The number of light reduced and electricity consumption from this exercise can translate into reduction of maintenance and electricity bill. The comparison of payback period for various energy saving techniques were discussed as well.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i3.pp1569-1575</dc:identifier><dc:identifier>10.11591/ijece.v9i3.pp1569-1575</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 3 (2019); 1569</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/17255/12377</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>