Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Automated medical surgical trolley

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 3 (2019)

DOI
10.11591/ijece.v9i3.pp1822-1831
ISSN
2088-8708, 2088-8708
Published
2019-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Operating theatre is a place in a hospital where surgical operations are conducted on patients by surgeons. In the operating theatre, the surgical equipment is placed on stainless steel table or on surgical instrument tray. However, during the operation accidents can occur where the surgical tools placed near to the surgeon could be accidentally be hit by them during the surgical operation. This may cause the surgical tools to fall on the floor which may lead to injuries. Hence, this paper presents an automatic medical surgical trolley for surgeons to grab operating tools easily. The proposed system is implemented for automaticmedical surgical trolley movement using Arduino Uno R3. The invention provides an automatic medical surgical trolley which comprises automatic guidance, a wireless controller, an obstacle avoiding detection device, a touch screen controller via smart phone, an IP camera, a trolley, an integrated power supply and a processor. The trolley with stainless steel shelves is ideal for use in clinical environments and operation theatres. Medical equipment is loaded in the trolley, the wireless remote drives the trolley to move forwards and backwards. Automatic visual guidance is achieved via an IP camera attached to the trolley and a touch screen controller via a smart phone. A large amount of space and a large number of materials are saved, the workload of medical workers will be greatly relieved, and the working efficiency will be improved.

Collaboration network of the authors

29 authors · 91 co-authorship links · 18 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Universitas Ahmad Dahlan
  • Universiti Putra Malaysia
  • University of Osijek
  • Multimedia University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Tole SutiknoUniversitas Ahmad Dahlan6
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka6
Mustafa ManapUniversiti Teknikal Malaysia Melaka6
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka5
Ahmad Sobri MudaUniversiti Putra Malaysia4
Jingwei TooUniversiti Teknikal Malaysia Melaka3
Haslinda MusaUniversiti Teknikal Malaysia Melaka3
A.S. HussinUniversiti Teknikal Malaysia Melaka2
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka2
Nor Nabilah Syazana Abdul RahmanUniversiti Teknikal Malaysia Melaka2
Nur Hasanah AliMultimedia University2
Shaarmila KandayaUniversiti Teknikal Malaysia Melaka2
Ezreen Farina ShairUniversiti Teknikal Malaysia Melaka2
Muhammad Izzat Ahmad SabriAffiliation unknown2
M.F. HabbanUniversiti Teknikal Malaysia Melaka1
P. MarzukiUniversiti Teknikal Malaysia Melaka1
A. R. SyafeezaUniversiti Teknikal Malaysia Melaka1
Yan Chiew WongUniversiti Teknikal Malaysia Melaka1
Ali Nur AlisaUniversiti Teknikal Malaysia Melaka1
M. M. IbrahimUniversiti Teknikal Malaysia Melaka1
Muhamad Faizal YaakubUniversiti Teknikal Malaysia Melaka1
Weihown TeeAffiliation unknown1
Srete NikolovskiUniversity of Osijek1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Automated medical surgical trolley</dc:title><dc:creator>Saad, N. M.</dc:creator><dc:creator>Abdullah, A. R.</dc:creator><dc:creator>Noor, N. S. M.</dc:creator><dc:creator>Hamid, N. A.</dc:creator><dc:creator>Syahmi, M. A. Muhammad</dc:creator><dc:creator>Ali, N. M.</dc:creator><dc:description>&lt;jats:p&gt;Operating theatre is a place in a hospital where surgical operations are conducted on patients by surgeons. In the operating theatre, the surgical equipment is placed on stainless steel table or on surgical instrument tray. However, during the operation accidents can occur where the surgical tools placed near to the surgeon could be accidentally be hit by them during the surgical operation. This may cause the surgical tools to fall on the floor which may lead to injuries. Hence, this paper presents an automatic medical surgical trolley for surgeons to grab operating tools easily. The proposed system is implemented for automaticmedical surgical trolley movement using Arduino Uno R3. The invention provides an automatic medical surgical trolley which comprises automatic guidance, a wireless controller, an obstacle avoiding detection device, a touch screen controller via smart phone, an IP camera, a trolley, an integrated power supply and a processor. The trolley with stainless steel shelves is ideal for use in clinical environments and operation theatres. Medical equipment is loaded in the trolley, the wireless remote drives the trolley to move forwards and backwards. Automatic visual guidance is achieved via an IP camera attached to the trolley and a touch screen controller via a smart phone. A large amount of space and a large number of materials are saved, the workload of medical workers will be greatly relieved, and the working efficiency will be improved.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i3.pp1822-1831</dc:identifier><dc:identifier>10.11591/ijece.v9i3.pp1822-1831</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 3 (2019); 1822</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/17266/12842</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>