Abstract

Electric power is the bedrock of our modern way of life. In Nigeria, power supply availability, sufficiency and reliability are major operational challenges. At the generation and transmission level, effort is made to ensure status monitoring and fault detection on the power network, but at the distribution level, particularly within domestic consumer communities there are no fault monitoring and detection devices except for HRC fuses at the feeder pillar. Unfortunately, these fuses are sometimes replaced by a copper wire bridge at some locations rendering the system unprotected and creating a great potential for transformer destruction on overload. This study is focused on designing an on-site power system monitoring device to be deployed on selected household entry power cables for detecting and indicating when phase off, low voltage, high voltage, over current, and blown fuse occurs on the building’s incomer line. The fault indication will help in reducing troubleshooting time and also ensure quick service restoration. After design implementation, the test result confirms design accuracy, device functionality and suitability as a low-cost solution to power supply system fault monitoring within local communities.

Collaboration network of the authors

16 authors · 41 co-authorship links · 17 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Covenant University
  • University of Ibadan
  • Namibia University of Science and Technology
  • University of Lagos
  • Lead City University
  • New Mexico State University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Isaac Adekunle SamuelCovenant University3
James KatendeNamibia University of Science and Technology3
C. O. A. AwosopeCovenant University2
Ayoade Felix AgbetuyiCovenant University2
Koto OmiloliCovenant University1
Isaac SamuelCovenant University1
Oghorchukwuyem ObiaziCovenant University1
Timilehin SanniCovenant University1
Anthony U. AdogheAffiliation unknown1
Adeola BalogunUniversity of Lagos1
Tobi SomefunAffiliation unknown1
Kayode Ebenezer OjoLead City University1
Seyi FanifosiNew Mexico State University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power distribution system fault monitoring device for supply networks in Nigeria</dc:title><dc:creator>Kareem, Olalekan Kabiru</dc:creator><dc:creator>Adekitan, Aderibigbe</dc:creator><dc:creator>Awelewa, Ayokunle</dc:creator><dc:description>&lt;jats:p&gt;Electric power is the bedrock of our modern way of life. In Nigeria, power supply availability, sufficiency and reliability are major operational challenges. At the generation and transmission level, effort is made to ensure status monitoring and fault detection on the power network, but at the distribution level, particularly within domestic consumer communities there are no fault monitoring and detection devices except for HRC fuses at the feeder pillar. Unfortunately, these fuses are sometimes replaced by a copper wire bridge at some locations rendering the system unprotected and creating a great potential for transformer destruction on overload. This study is focused on designing an on-site power system monitoring device to be deployed on selected household entry power cables for detecting and indicating when phase off, low voltage, high voltage, over current, and blown fuse occurs on the building’s incomer line. The fault indication will help in reducing troubleshooting time and also ensure quick service restoration. After design implementation, the test result confirms design accuracy, device functionality and suitability as a low-cost solution to power supply system fault monitoring within local communities.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i4.pp2803-2812</dc:identifier><dc:identifier>10.11591/ijece.v9i4.pp2803-2812</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 4 (2019); 2803</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/14322/13109</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>