Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Evaluation of Power Quality Issues in grid Connected PV Systems

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 6 No. 4 (2016)

DOI
10.11591/ijece.v6i4.pp1412-1420
ISSN
2088-8708, 2088-8708
Published
2016-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper deals with the evaluation of power quality issues in grid connected PV systems. This paper also presents complete simulation, modeling and control of three phase grid connected solar PV module with Maximum Power Point Tracking. Perturb and Observe (P&O) method has been used for Maximum Power Point Tracking. In the proposed model DC bus voltage control, harmonic mitigation and power factor control are discussed as power quality issues. The simulation results are shown in the graphical waveforms and simulation is performed in MATLAB using SIMULINK environment and PSB toolboxes.

Collaboration network of the authors

3 authors · 3 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Uttarakhand Technical University
  • GLA University
  • Ajay Kumar Garg Engineering College
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Evaluation of Power Quality Issues in grid Connected PV Systems</dc:title><dc:creator>Varshney, Gunjan</dc:creator><dc:creator>Chauhan, D S</dc:creator><dc:creator>Dave, M P</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;This paper deals with the evaluation of power quality issues in grid connected PV systems. This paper also presents  complete simulation, modeling and control of three phase grid connected solar PV module with Maximum Power Point Tracking. Perturb and Observe (P&amp;amp;amp;O) method has been used for Maximum Power Point Tracking. In the proposed model DC bus voltage control , harmonic mitigation and power factor control are discussed as power quality issues. The simulation results are shown in the graphical waveforms and simulation is performed in MATLAB using SIMULINK environment and PSB toolboxes. &amp;lt;strong&amp;gt; &amp;lt;/strong&amp;gt;&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i4.pp1412-1420</dc:identifier><dc:identifier>10.11591/ijece.v6i4.pp1412-1420</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 4 (2016); 1412</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/707/467</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>