Melola Discovery

← Melola Discovery

Akses terbuka Jurnal Tanpa peringkat SINTA

Heat transfer through building envelope materials and their effect on indoor air temperatures in tropics

Journal of Science and Applicative Technology · Vol. 5 No. 2 (2021)

DOI
10.35472/jsat.v5i2.630
ISSN
2581-0545
Terbit
2021-10-12
Penerbit
Institut Teknologi Sumatra
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

High thermal mass modern building materials are unsuitable to be used in the tropics due to their thermos-physical properties and the ability in absorbing solar radiation, storing and transferring heat into the building, affecting the high indoor air temperature, hence, reducing thermal comfort. However, due to the high demand for building, utilization of this material is avoidable. This study investigated the heat transfer through building envelope materials and their effect on the indoor air temperature of the building through field measurement using a thermal camera and a handle wind meter. The results found that the ceiling is the part of the building which gained the highest indoor surface temperature which reaches 38.6 °C at the apex point at 2pm but decreased significantly to 30.4 °C at 6 pm. Meanwhile, the inner of the northeast wall gained 33.1 °C at the peak temperature and stayed above 30 °C until 10 pm. The indoor air temperature of this unit housing was 36.3 °C at 2 pm with the temperature difference between outdoor and indoor was 2.5 °C. At night, the indoor air temperature was 3.8 °C higher than the outside temperature.

Jaringan kolaborasi para penulis

8 penulis · 22 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sumatera Institute of Technology
  • Dong-A University
  • Democritus University of Thrace
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Septi MaulidyahSumatera Institute of Technology1
Dadang HartabelaSumatera Institute of Technology1
Dean D.T. ElcieloSumatera Institute of Technology1
Cipta VidyanaSumatera Institute of Technology1
Indah PrastiwiSumatera Institute of Technology1
Andreas MatzarakisDemocritus University of Thrace1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2581-0545/works, pertama di-harvest 5 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Heat transfer through building envelope materials and their effect on indoor air temperatures in tropics</dc:title><dc:creator>Arminda, Wenny</dc:creator><dc:creator>Kamaruddin, Maqbul</dc:creator><dc:description>&lt;jats:p&gt;High thermal mass modern building materials are unsuitable to be used in the tropics due to their thermos-physical properties and the ability in absorbing solar radiation, storing and transferring heat into the building, affecting the high indoor air temperature, hence, reducing thermal comfort. However, due to the high demand for building, utilization of this material is avoidable. This study investigated the heat transfer through building envelope materials and their effect on the indoor air temperature of the building through field measurement using a thermal camera and a handle wind meter. The results found that the ceiling is the part of the building which gained the highest indoor surface temperature which reaches 38.6 °C at the apex point at 2pm but decreased significantly to 30.4 °C at 6 pm. Meanwhile, the inner of the northeast wall gained 33.1 °C at the peak temperature and stayed above 30 °C until 10 pm. The indoor air temperature of this unit housing was 36.3 °C at 2 pm with the temperature difference between outdoor and indoor was 2.5 °C. At night, the indoor air temperature was 3.8 °C higher than the outside temperature.&lt;/jats:p&gt;</dc:description><dc:publisher>Institut Teknologi Sumatra</dc:publisher><dc:date>2021-10-12</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.35472/jsat.v5i2.630</dc:identifier><dc:identifier>10.35472/jsat.v5i2.630</dc:identifier><dc:source>Journal of Science and Applicative Technology; Vol 5 No 2 (2021); 403</dc:source><dc:source>2581-0545</dc:source><dc:relation>https://journal.itera.ac.id/index.php/jsat/article/download/630/226</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>