Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Performance Evaluation of Three PID Controller Tuning Algorithm on a Process Plant

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 5 No. 5 (2015)

DOI
10.11591/ijece.v5i5.pp1075-1082
ISSN
2088-8708, 2088-8708
Published
2015-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Accurate tuning of controller in industrial process operation is prerequisite to system smooth operation which directly reduce process variability, improved efficiency, reduced energy costs, and increased production rates. Performance evaluation of a model based PID controller tuning algorithm on a chemical process plant is presented in this paper. The control action of three different PID controller tuning algorithms namely; Hagglund-Astrom, Cohen and Coon, and Ziegler-Nichols on the process plant was examined in a closed loop control configuration under normal operating condition and in the face of disturbance. LabVIEW software was used to model a chemical process plant from open loop control test data. The time domain response analysis of the controllers shows that each tuning algorithm exhibit different time response. Ziegler-Nichols algorithm shows the best performance with fastest rise time, settling time and was able to restore the system back to normal operating condition in a short time when subjected to disturbance compare to Cohen & Coon controller and Hagglund-Astrom algorithm settings.

Collaboration network of the authors

9 authors · 15 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Ilorin
  • Universiti Teknologi Petronas
  • National Agency for Science and Engineering Infrastructure
  • Ahmadu Bello University
  • University of Technology Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nor Zaihar YahayaUniversiti Teknologi Petronas1
Nordin B. SaadUniversiti Teknologi Petronas1
Mohd Wazir MustafaUniversity of Technology Malaysia1
Sani SalisuAhmadu Bello University1
Mamunu MustaphaAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Performance Evaluation of Three PID Controller Tuning Algorithm on a Process Plant</dc:title><dc:creator>Ibrahim, Oladimeji</dc:creator><dc:creator>Amuda, Sulyman A. Y.</dc:creator><dc:creator>Mohammed, Olatunji O.</dc:creator><dc:creator>Kareem, Ganiyu A.</dc:creator><dc:description>&lt;jats:p&gt;Accurate tuning of controller in industrial process operation is prerequisite to system smooth operation which directly reduce process variability, improved efficiency, reduced energy costs, and increased production rates. Performance evaluation of a model based PID controller tuning algorithm on a chemical process plant is presented in this paper. The control action of three different PID controller tuning algorithms namely; Hagglund-Astrom, Cohen and Coon, and Ziegler-Nichols on the process plant was examined in a closed loop control configuration under normal operating condition and in the face of disturbance. LabVIEW software was used to model a chemical process plant from open loop control test data. The time domain response analysis of the controllers shows that each tuning algorithm exhibit different time response. Ziegler-Nichols algorithm shows the best performance with fastest rise time, settling time and was able to restore the system back to normal operating condition in a short time when subjected to disturbance compare to Cohen &amp;amp;amp; Coon controller and Hagglund-Astrom algorithm settings.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2015-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v5i5.pp1075-1082</dc:identifier><dc:identifier>10.11591/ijece.v5i5.pp1075-1082</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 5 No 5 (2015); 1075</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5728/4605</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>