Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Dual technique of reconfiguration and capacitor placement for distribution system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 1 (2020)

DOI
10.11591/ijece.v10i1.pp80-90
ISSN
2088-8708, 2088-8708
Published
2020-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Radial Distribution System (RDS) suffer from high real power losses and lower bus voltages. Distribution System Reconfiguration (DSR) and Optimal Capacitor Placement (OCP) techniques are ones of the most economic and efficient approaches for loss reduction and voltage profile improvement while satisfy RDS constraints. The advantages of these two approaches can be concentrated using of both techniques together. In this study two techniques are used in different ways. First, the DSR technique is applied individually. Second, the dual technique has been adopted of DSR followed by OCP in order to identify the technique that provides the most effective performance. Three optimization algorithms have been used to obtain the optimal design in individual and dual technique. Two IEEE case studies (33bus, and 69 bus) used to check the effectiveness of proposed approaches. A Direct Backward Forward Sweep Method (DBFSM) has been used in order to calculate the total losses and voltage of each bus. Results show the capability of the proposed dual technique using Modified Biogeography Based Optimization (MBBO) algorithm to find the optimal solution for significant loss reduction and voltage profile enhancement. In addition, comparisons with literature works done to show the superiority of proposed algorithms in both techniques.

Collaboration network of the authors

6 authors · 7 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Middle Technical University
  • Al-Furat Al-Awsat Technical University
  • Northern Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ali Abduladheem IsmailMiddle Technical University1
Ahmed Jadaan AliNorthern Technical University1
Firas Saaduldeen AhmedMiddle Technical University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Dual technique of reconfiguration and capacitor placement for distribution system</dc:title><dc:creator>Kadom, Haider Fathi</dc:creator><dc:creator>Hussain, Ali Nasser</dc:creator><dc:creator>Al-Jubori, Waleed Khalid Shakir</dc:creator><dc:description>&lt;jats:p&gt;Radial Distribution System (RDS) suffer from high real power losses and lower bus voltages. Distribution System Reconfiguration (DSR) and Optimal Capacitor Placement (OCP) techniques are ones of the most economic and efficient approaches for loss reduction and voltage profile improvement while satisfy RDS constraints. The advantages of these two approaches can be concentrated using of both techniques together. In this study two techniques are used in different ways. First, the DSR technique is applied individually. Second, the dual technique has been adopted of DSR followed by OCP in order to identify the technique that provides the most effective performance. Three optimization algorithms have been used to obtain the optimal design in individual and dual technique. Two IEEE case studies (33bus, and 69 bus) used to check the effectiveness of proposed approaches. A Direct Backward Forward Sweep Method (DBFSM) has been used in order to calculate the total losses and voltage of each bus. Results show the capability of the proposed dual technique using Modified Biogeography Based Optimization (MBBO) algorithm to find the optimal solution for significant loss reduction and voltage profile enhancement. In addition, comparisons with literature works done to show the superiority of proposed algorithms in both techniques.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i1.pp80-90</dc:identifier><dc:identifier>10.11591/ijece.v10i1.pp80-90</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 1 (2020); 80</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/19330/13406</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>