The direct power control of three-phase AC-DC converter under unbalance voltage condition

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 6 (2019)

DOI
10.11591/ijece.v9i6.pp5107-5114
ISSN
2088-8708, 2088-8708
Published
2019-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper has presents the integrated approach for three-phase PWM AC-DC converter for obtaining the symmetrical components under unbalanced supply condition. The input structures for conventional direct power control have been modified with three simpler sequence networks instead it coupled by a detailed three-phase system method. In the cases of an unbalanced three-phase system, it causes the presence of unbalanced current and voltages thus produce the negative components on the grid voltage. Otherwise, the unbalance voltage in a three-phase power system causes severe performance degradation of a grid-connected VSI. Therefore, the imbalance voltage can be resolved by separating from the individual elements of voltage and current into symmetrical components called as a sequencing network. Consequently, the input power is relatively improved during unbalanced condition. It proven through the measurement of Total Harmonic Distortion (THD) from the conventional direct power control in individual elements is much higher compared than it resolved in separate components. Therefore, three symmetrical components are necessary for imbalance supply condition to obtaining almost sinusoidal grid currents.

Collaboration network of the authors

16 authors · 41 co-authorship links · 14 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Sains Malaysia
  • Universitas Ahmad Dahlan
  • University of Technology Malaysia
  • Universiti Malaysia Perlis
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Raja Nor Firdaus Kashfi Raja OthmanUniversiti Teknikal Malaysia Melaka4
Nor Aishah Md ZukiUniversiti Teknikal Malaysia Melaka4
Nurfaezah AbdullahUniversiti Teknikal Malaysia Melaka4
Tole SutiknoUniversitas Ahmad Dahlan3
T. C. KwangUniversiti Teknikal Malaysia Melaka2
Mohd Luqman Mohd Jamil‬Universiti Teknikal Malaysia Melaka2
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka1
Nik Rumzi Nik IdrisUniversity of Technology Malaysia1
Muhammad Zaid AihsanUniversiti Malaysia Perlis1
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka1
Muhammad Hafeez Mohamed HaririUniversiti Sains Malaysia1
Lim Kean BoonUniversiti Sains Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>The direct power control of three-phase AC-DC converter under unbalance voltage condition</dc:title><dc:creator>Yusoff, Nor Azizah</dc:creator><dc:creator>Razali, Azziddin M.</dc:creator><dc:creator>Karim, Kasrul Abdul</dc:creator><dc:creator>Jidin, Auzani</dc:creator><dc:description>&lt;jats:p&gt;This paper has presents the integrated approach for three-phase PWM AC-DC converter for obtaining the symmetrical components under unbalanced supply condition. The input structures for conventional direct power control have been modified with three simpler sequence networks instead it coupled by a detailed three-phase system method. In the cases of an unbalanced three-phase system, it causes the presence of unbalanced current and voltages thus produce the negative components on the grid voltage. Otherwise, the unbalance voltage in a three-phase power system causes severe performance degradation of a grid-connected VSI. Therefore, the imbalance voltage can be resolved by separating from the individual elements of voltage and current into symmetrical components called as a sequencing network. Consequently, the input power is relatively improved during unbalanced condition. It proven through the measurement of Total Harmonic Distortion (THD) from the conventional direct power control in individual elements is much higher compared than it resolved in separate components. Therefore, three symmetrical components are necessary for imbalance supply condition to obtaining almost sinusoidal grid currents.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i6.pp5107-5114</dc:identifier><dc:identifier>10.11591/ijece.v9i6.pp5107-5114</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 6 (2019); 5107</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/19362/13316</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>