Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Backstepping based power control of a three-phase Single-stage Grid-connected PV system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 6 (2019)

DOI
10.11591/ijece.v9i6.pp4738-4748
ISSN
2088-8708, 2088-8708
Published
2019-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

In order to reduce costs while maintaining superior performance, this paper presents a new control methodology of a three-phase grid connected photovoltaic system without using the intermediary DC/DC converter. Based on the synchronized nonlinear model of the whole photovoltaic system, two controllers have been proposed for the three-phase inverter in order to ensure the operation of the PV system at the maximum power point with unity power factor and minimum grid disturbance. Grid synchronization has been ensured by a three-phase 2 nd order PLL (Phase-Locked Loop). The stability of each controller is demonstrated by means of Lyapunov analysis and evaluated under changing atmospheric conditions using the Matlab/Simulink environment, the simulation results clearly demonstrate the performance provided by each controller.

Collaboration network of the authors

22 authors · 53 co-authorship links · 22 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Université Hassan 1er
  • University of Hassan II Casablanca
  • Université Moulay Ismail de Meknes
  • Royal Military College of Canada
  • École Supérieure d'Électronique de l'Ouest
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mohamed AboulfatahUniversité Hassan 1er4
Hicham BahriUniversity of Hassan II Casablanca3
Hamid BennisUniversité Moulay Ismail de Meknes2
Abdelghani BoudaoudUniversité Hassan 1er1
M. El HaroussiAffiliation unknown1
Mohamed LatrachÉcole Supérieure d'Électronique de l'Ouest1
Mohamed IhamjiUniversité Hassan 1er1
Mostafa HefnawiRoyal Military College of Canada1
Ahmed MoutabirUniversity of Hassan II Casablanca1
Jamal ZbitouUniversité Hassan 1er1
Khalifa EchchakhaouiUniversité Hassan 1er1
Bouchaib RachedUniversité Hassan 1er1
Mustapha ElharoussiUniversité Hassan 1er1
Abderrahim TaouniUniversity of Hassan II Casablanca1
Abdelwahed TouatiUniversity of Hassan II Casablanca1
Radouane MajdoulUniversity of Hassan II Casablanca1
Abderrahmane OuchattiUniversity of Hassan II Casablanca1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Backstepping based power control of a three-phase Single-stage Grid-connected PV system</dc:title><dc:creator>Malah, Mohammed El</dc:creator><dc:creator>Ba-razzouk, Abdellfattah</dc:creator><dc:creator>Guisser, M’hammed</dc:creator><dc:creator>Abdelmounim, Elhassane</dc:creator><dc:creator>Madark, Mhamed</dc:creator><dc:description>&lt;jats:p&gt;In order to reduce costs while maintaining superior performance, this paper presents a new control methodology of a three-phase grid connected photovoltaic system without using the intermediary DC/DC converter. Based on the synchronized nonlinear model of the whole photovoltaic system, two controllers have been proposed for the three-phase inverter in order to ensure the operation of the PV system at the maximum power point with unity power factor and minimum grid disturbance. Grid synchronization has been ensured by a three-phase 2&amp;lt;sup&amp;gt;nd&amp;lt;/sup&amp;gt; order PLL (Phase-Locked Loop). The stability of each controller is demonstrated by means of Lyapunov analysis and evaluated under changing atmospheric conditions using the Matlab/Simulink environment, the simulation results clearly demonstrate the performance provided by each controller.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i6.pp4738-4748</dc:identifier><dc:identifier>10.11591/ijece.v9i6.pp4738-4748</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 6 (2019); 4738</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/14818/13171</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>