Torque improvement of PM motor with semi-cycle stator design using 2D-finite element analysis

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 6 (2019)

DOI
10.11591/ijece.v9i6.pp5060-5067
ISSN
2088-8708, 2088-8708
Published
2019-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper presents sizing approaches to improve output torque performance in PM motor when partial stator body is removed. As the output torque performance is directly proportional to the electric loading, Q, modification on stator geometry affects the output torque performance and special procedures have to be taken to restore the desired output torque capability. Influences of split ratio, tooth body width, airgap and magnet thickness of magnet in PM motor with asymmetry stator design are carried out and the performance verification are referred to the back-emf, average output torque, torque ripple as well as cogging torque. From the investigation using 2D-Finite Element Analysis, optimum size of tooth body width and optimum number of coil turns result better output torque while other sizing approaches result no significant change as quick saturation took place.

Collaboration network of the authors

14 authors · 36 co-authorship links · 10 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Universitas Ahmad Dahlan
  • University of Technology Malaysia
  • Universiti Malaysia Perlis
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Tole SutiknoUniversitas Ahmad Dahlan2
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka2
Azziddin Mohamad RazaliUniversiti Teknikal Malaysia Melaka2
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka2
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka1
Nik Rumzi Nik IdrisUniversity of Technology Malaysia1
Raja Nor Firdaus Kashfi Raja OthmanUniversiti Teknikal Malaysia Melaka1
Nor Aishah Md ZukiUniversiti Teknikal Malaysia Melaka1
Nurfaezah AbdullahUniversiti Teknikal Malaysia Melaka1
Muhammad Zaid AihsanUniversiti Malaysia Perlis1
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Torque improvement of PM motor with semi-cycle stator design using 2D-finite element analysis</dc:title><dc:creator>C., Kwang T.</dc:creator><dc:creator>Mohd Jamil, Mohd Luqman</dc:creator><dc:creator>Jidin, Auzani</dc:creator><dc:description>&lt;jats:p&gt;This paper presents sizing approaches to improve output torque performance in PM motor when partial stator body is removed. As the output torque performance is directly proportional to the electric loading, Q, modification on stator geometry affects the output torque performance and special procedures have to be taken to restore the desired output torque capability. Influences of split ratio, tooth body width, airgap and magnet thickness of  magnet in PM motor with asymmetry stator design are carried out and the performance verification are referred to the back-emf, average output torque, torque ripple as well as cogging torque. From the investigation using 2D-Finite Element Analysis, optimum size of tooth body width and optimum number of coil turns result better output torque while other sizing approaches result no significant change as quick saturation took place.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i6.pp5060-5067</dc:identifier><dc:identifier>10.11591/ijece.v9i6.pp5060-5067</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 6 (2019); 5060</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/19228/13334</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>