Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Optimal number and location of UPFC devices to enhence voltage profile and minimizing losses in electrical power systems

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 9 No. 5 (2019)

DOI
10.11591/ijece.v9i5.pp3981-3992
ISSN
2722-2578, 2088-8708
Published
2019-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The fast increase of loads around the world has made electrical networks more and more complex and difficult to operate close to its capacities. This is has led to many problems such as voltage collapse and energy losses. Therefore, flexible alternating current transmission systems (FACTS) are considred as a best solution for solving these problems. Unified Power Flow Controller UPFC is one of the most important and powerful FACTS devices due to its ability to increase the transmission capacity of the power system and reduce the total line losses. The problem of optimizing its number, location and size has become an important requirement for best advantages of this device. In this paper, a proposed relationship to identify the maximum number of FACTS devices that can be installed for a given power network is introduced in the search process code to determine the optimal number, optimal placement and size of UPFC device to enhance voltages profile and reduce overall system losses in the standard IEEE 14 bus test system using genetic algorithm (GA). The obtained results show clearly that all control parameters of UPFCs in each case are within their limits, and whenever the number of UPFCs installed increases, both voltage deviation and total losses well decreases. They also show that the application of the proposed relationship in the search process code facilitates greatly the search for optimal number, optimal placement and size of UPFC devices and reduces the calculation time. On the other hand, the obtained results has been scientifically justified and compared with other works reported in the literature.

Collaboration network of the authors

10 authors · 13 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University Frères Mentouri Constantine 1
  • Mohamed-Cherif Messaadia University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Boucetta Abdou AbdallahAffiliation unknown1
Boucetta Abd AllahUniversity Frères Mentouri Constantine 11
Fetissi SelwaUniversity Frères Mentouri Constantine 11
Labed ImenUniversity Frères Mentouri Constantine 11
Abdellah DraidiUniversity Frères Mentouri Constantine 11
Omar FeddaouiMohamed-Cherif Messaadia University1
Riad ToufoutiMohamed-Cherif Messaadia University1
Salima MezianeMohamed-Cherif Messaadia University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Optimal number and location of UPFC devices to enhence voltage profile and minimizing losses in electrical power systems</dc:title><dc:creator>Hocine, Sekhane</dc:creator><dc:creator>Djamel, Labed</dc:creator><dc:description>&lt;jats:p&gt;The fast increase of loads around the world has made electrical networks more and more complex and difficult to operate close to its capacities. This is has led to many problems such as voltage collapse and energy losses. Therefore, flexible alternating current transmission systems (FACTS) are considred as a best solution for solving these problems. Unified Power Flow Controller UPFC is one of the most important and powerful FACTS devices due to its ability to increase the transmission capacity of the power system and reduce the total line losses. The problem of optimizing its number, location and size has become an important requirement for best advantages of this device. In this paper, a proposed relationship to identify the maximum number of FACTS devices that can be installed for a given power network is introduced in the search process code to determine the optimal number, optimal placement and size of UPFC device to enhance voltages profile and reduce overall system losses in the standard IEEE 14 bus test system using genetic algorithm (GA). The obtained results show clearly that all control parameters of UPFCs in each case are within their limits, and whenever the number of UPFCs installed increases, both voltage deviation and total losses well decreases. They also show that the application of the proposed relationship in the search process code facilitates greatly the search for optimal number, optimal placement and size of UPFC devices and reduces the calculation time. On the other hand, the obtained results has been scientifically justified and compared with other works reported in the literature.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2019-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v9i5.pp3981-3992</dc:identifier><dc:identifier>10.11591/ijece.v9i5.pp3981-3992</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 9 No 5 (2019); 3981</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/15587/12999</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>