Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Transient Phenomena during the Three-Phase 300MVA Transformer Energization on the Transmission Network

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 6 No. 6 (2016)

DOI
10.11591/ijece.v6i6.pp2499-2505
ISSN
2088-8708, 2088-8708
Published
2016-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Connecting the transformer to the network may incur inrush current, which is significantly higher than the rated current of the transformer. The main cause of this phenomenon lies in the nonlinearity of the magnetic circuit. The value of the inrush current depends of the time moment of the energization and the residual magnetism in the transformer core. While connecting, the operating point of the magnetization characteristic can be found deep in the saturation region resulting in occurrence of large transformer currents that can trigger the transformer protection. Tripping of protection immediately after the transformer energization raises doubts about the transformer health. Inrush current can cause a number of other disadvantages such as the negative impact on other transformers connected on the same busbar; the increase of the transformer noise due to the large current value, the increase of the voltage drops in the network. The paper presents a simulation of the 300 MVA transformer energization using the MATLAB/Simulink software.

Collaboration network of the authors

14 authors · 28 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Osijek
  • Universiti Teknikal Malaysia Melaka
  • Fond za zaštitu okoliša i energetsku učinkovitost
  • Regional Energy Agency
  • Universitas Ahmad Dahlan
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Goran KneževićUniversity of Osijek6
Ljubomir MajdandžićFond za zaštitu okoliša i energetsku učinkovitost6
Dragan MlakićAffiliation unknown5
Zoran BausUniversity of Osijek4
Marko VukobratovićUniversity of Osijek2
Goran SlipacAffiliation unknown2
Jurica PerkoRegional Energy Agency1
Tole SutiknoUniversitas Ahmad Dahlan1
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka1
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka1
Mustafa ManapUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Transient Phenomena during the Three-Phase 300MVA Transformer Energization on the Transmission Network</dc:title><dc:creator>Alibašić, Emir</dc:creator><dc:creator>Marić, Predrag</dc:creator><dc:creator>Nikolovski, Srete N</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Connecting the transformer to the network may incur inrush current, which is significantly higher than the rated current of the transformer. The main cause of this phenomenon lies in the nonlinearity of the magnetic circuit. The value of the inrush current depends of the time moment of the energization and the residual magnetism in the transformer core. While connecting, the operating point of the magnetization characteristic can be found deep in the saturation region resulting in occurrence of large transformer currents that can trigger the transformer protection. Tripping of protection immediately after the transformer energization raises doubts about the transformer health. Inrush current can cause a number of other disadvantages such as the negative impact on other transformers connected on the same busbar; the increase of the transformer noise due to the large current value, the increase of the voltage drops in the network. The paper presents a simulation of the 300 MVA transformer energization using the MATLAB/Simulink software.&amp;lt;/p&amp;gt;&amp;lt;p&amp;gt; &amp;lt;/p&amp;gt;&amp;lt;p&amp;gt; &amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i6.pp2499-2505</dc:identifier><dc:identifier>10.11591/ijece.v6i6.pp2499-2505</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 6 (2016); 2499</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5861/5519</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>