Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Power Quality Enhancement of Integration Photovoltaic Generator to Grid under Variable Solar Irradiance Level using MPPT-Fuzzy

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 6 No. 6 (2016)

DOI
10.11591/ijece.v6i6.pp2629-2642
ISSN
2088-8708, 2088-8708
Published
2016-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

The paper presents power quality enhancement on low voltage of three phase grid caused by PV generator integration under variabel solar irradiance level on constant temperature and load. MPPT Fuzzy helps to generate duty cycle to control DC/DC boost converter of PV generators. This model was expected to improve power quality due to unbalance voltage and current, low voltage and current harmonics, and low input power factor. There were eigth scenarios PV generator connected to three phase grid using MPPT Fuzzy and compared with MPPT P and O. The research results that application of two methods on different irradiance and PV generator integration level produces unbalanced voltage value stable at 0%. At the same conditions, the use of MPPT Fuzzy results unbalanced current was greater than MPPT P and O. On solar irradiance level fixed, the greater number of PV generator connected to three-phase grid, then value of average voltage and current harmonics (THD) will increases. At the level of solar radiation increases, average grid voltage and current THD also have increased. The average grid voltage and current THD was reduced after using MPPT Fuzzy. The application of MPPT Fuzzy was able to enhance profile of grid voltage and current THD due to integration of a number of PV generator to three phase grid corresponding with IEEE Standard 519-1992. MPPT Fuzzy was capable to improve input power factor better than MPPT P and O.

Collaboration network of the authors

7 authors · 9 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Institut Teknologi Sepuluh Nopember
  • Universitas Bhayangkara Surabaya
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Adiananda AdianandaUniversitas Bhayangkara Surabaya2
Hudan StudiawanInstitut Teknologi Sepuluh Nopember1
Royyana Muslim IjtihadieInstitut Teknologi Sepuluh Nopember1
Ontoseno PenangsangInstitut Teknologi Sepuluh Nopember1
Adi SoeprijantoInstitut Teknologi Sepuluh Nopember1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power Quality Enhancement of Integration Photovoltaic Generator to Grid under Variable Solar Irradiance Level  using MPPT-Fuzzy</dc:title><dc:creator>Amirullah, Amirullah</dc:creator><dc:creator>Kiswantono, Agus</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;The paper presents power quality enhancement on low voltage of three phase grid caused by PV generator integration under variabel solar irradiance level on constant temperature and load. MPPT Fuzzy helps to generate duty cycle to control DC/DC boost converter of PV generators. This model was expected to improve power quality due to unbalance voltage and current, low voltage and current harmonics, and low input power factor. There were eigth scenarios PV generator connected to three phase grid using MPPT Fuzzy and compared with MPPT P and O. The research results that application of two methods on different irradiance and PV generator integration level produces unbalanced voltage value stable at 0%. At the same conditions, the use of MPPT Fuzzy results unbalanced current was greater than MPPT P and O. On solar irradiance level fixed, the greater number of PV generator connected to three-phase grid, then value of average voltage and current harmonics (THD) will increases. At the level of solar radiation increases, average grid voltage and current THD also have increased. The average grid voltage and current THD was reduced after using MPPT Fuzzy. The application of MPPT Fuzzy was able to enhance profile of grid voltage and current THD due to integration of a number of PV generator to three phase grid corresponding with IEEE Standard 519-1992. MPPT Fuzzy was capable to improve input power factor better than MPPT P and O.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i6.pp2629-2642</dc:identifier><dc:identifier>10.11591/ijece.v6i6.pp2629-2642</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 6 (2016); 2629</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5874/5533</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>