Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Model-based Automatic Segmentation of Ascending Aorta from Multimodality Medical Data

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 6 No. 6 (2016)

DOI
10.11591/ijece.v6i6.pp3161-3173
ISSN
2088-8708, 2088-8708
Published
2016-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Automatic Ascending Aorta Segmentation is one of the important steps towards automatic segmentation of the whole cardiac tree. This paper presents a novel approach for the automatic segmentation of the ascending aorta from two imaging modalities: CTA (Computed Tomography Angiography) and PC-MRI (Phase-Contrast Magnetic Resonance Images). The novel approach is an algorithm that works without the need for setting manual seed points or applying preprocessing steps or setting a region of interest. Instead, the proposed algorithm automatically detects and segments the ascending aorta using an ascending aorta model built from its anatomical features. The proposed segmentation algorithm begins with aorta detection through features model fitting augmented with Hough transform, where the ascending aorta is identified from the descending aorta and any other circular structures based on the proposed model. After detection, the whole ascending aorta is segmented up from the aortic arch down to the ostia points using a novel automatic seeded region growing algorithm. The proposed algorithm is fully automatic, works in real-time and robust as parameters used are the same for all the tested datasets. The detection and segmentation of the ascending aorta succeeded in all test cases acquired from the two imaging modalities; proving the robustness of the proposed ascending aorta model and algorithm for the automatic segmentation process even on data from different modalities and different scanner types. The accuracy of the segmentation has a mean Dice Similarity Coefficient (DSC) of 94.72% for CTA datasets and 97.13% for PC-MRI datasets.

Collaboration network of the authors

6 authors · 9 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Ain Shams University
  • Jouf University
  • South Valley University
  • Al Baha University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Fulayjan AlanaziJouf University1
Ahmed ElhadadSouth Valley University1
A. GhareebAl Baha University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Model-based Automatic Segmentation of Ascending Aorta from Multimodality Medical Data</dc:title><dc:creator>Seada, Noha</dc:creator><dc:creator>Hamad, Safwat</dc:creator><dc:creator>Mostafa, Mostafa G. M.</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Automatic Ascending Aorta Segmentation is one of the important steps towards automatic segmentation of the whole cardiac tree. This paper presents a novel approach for the automatic segmentation of the ascending aorta from two imaging modalities: CTA (Computed Tomography Angiography) and PC-MRI (Phase-Contrast Magnetic Resonance Images). The novel approach is an algorithm that works without the need for setting manual seed points or applying preprocessing steps or setting a region of interest. Instead, the proposed algorithm automatically detects and segments the ascending aorta using an ascending aorta model built from its anatomical features. The proposed segmentation algorithm begins with aorta detection through features model fitting augmented with Hough transform, where the ascending aorta is identified from the descending aorta and any other circular structures based on the proposed model. After detection, the whole ascending aorta is segmented up from the aortic arch down to the ostia points using a novel automatic seeded region growing algorithm. The proposed algorithm is fully automatic, works in real-time and robust as parameters used are the same for all the tested datasets. The detection and segmentation of the ascending aorta succeeded in all test cases acquired from the two imaging modalities; proving the robustness of the proposed ascending aorta model and algorithm for the automatic segmentation process even on data from different modalities and different scanner types. The accuracy of the segmentation has a mean Dice Similarity Coefficient (DSC) of 94.72% for CTA datasets and 97.13% for PC-MRI datasets.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i6.pp3161-3173</dc:identifier><dc:identifier>10.11591/ijece.v6i6.pp3161-3173</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 6 (2016); 3161</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5937/5623</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>