This paper examines the frequency response of power plant grounding system exposed to the lightning current. Large amount of current generated by the stroke flow in the grounding system of power plant and dissipate in the soil. The electric and magnetic field generated by such high voltages and currents may cause damage of equipment and may be dangerous for the personnel in power plant. For the every given frequency obtained using Fast Fourier Transformation (FFT) of lightning current impulse, electromagnetic field theory approach is used to solve Maxell’s equation and compute scalar potential, electric and magnetic field. Also, the influence of the point in which lightning current is diffused in the grounding system is presented. Three dimensional plots of spatial distribution of scalar potential, electric and magnetic field are presented. The time domain response of scalar potential, electric and magnetic field on one profile is also presented.

Collaboration network of the authors

14 authors · 28 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Osijek
  • Universiti Teknikal Malaysia Melaka
  • Fond za zaštitu okoliša i energetsku učinkovitost
  • Regional Energy Agency
  • Universitas Ahmad Dahlan
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Dragan MlakićAffiliation unknown6
Ljubomir MajdandžićFond za zaštitu okoliša i energetsku učinkovitost5
Emir AlibašićAffiliation unknown4
Predrag MarićUniversity of Osijek3
Marko VukobratovićUniversity of Osijek2
Goran SlipacAffiliation unknown1
Jurica PerkoRegional Energy Agency1
Tole SutiknoUniversitas Ahmad Dahlan1
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka1
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka1
Mustafa ManapUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Frequency and Time Response of Power Plant Grounding System Exposed to Lightning Strike</dc:title><dc:creator>Nikolovski, Srete N</dc:creator><dc:creator>Baus, Zoran</dc:creator><dc:creator>Knežević, Goran</dc:creator><dc:description>&lt;jats:p&gt;This paper examines the frequency response of power plant grounding system exposed to the lightning current. Large amount of current generated by the stroke flow in the grounding system of power plant and dissipate in the soil.  The electric and magnetic field generated by such high voltages and currents may cause damage of equipment and may be dangerous for the personnel in power plant.  For the every given frequency obtained using Fast Fourier Transformation (FFT) of lightning current impulse, electromagnetic field theory approach is used to solve Maxell’s equation and compute scalar potential, electric and magnetic field. Also, the influence of the point in which lightning current is diffused in the grounding system is presented. Three dimensional plots of spatial distribution of scalar potential, electric and magnetic field are presented. The time domain response of scalar potential, electric and magnetic field on one profile is also presented.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i2.pp512-525</dc:identifier><dc:identifier>10.11591/ijece.v6i2.pp512-525</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 2 (2016); 512</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/132/148</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>