Abstract

In order to validating the new three-phase High voltage power supply for microwave generators with one magnetron by phase, this paper presents a new validation approach to evaluate the proposed model with several evaluations. This approach is based on the calculation and measurement of the performance and the power factor of this new three-phase power supply, also the study of the operation of this new system in case of failure. The design of this power supply is composed of new three-phase transformer with magnetic shunt, supplying by phase a voltage doubler cell composed of a capacitor and a diode. Each cell in turn, supplies a single magnetron. In this paper we have presented the new three-phase transformer by its equivalent model; it’s a π quadruple model composed of storable inductances able to translating the nonlinear saturation phenomena for stabilization of the magnetron current. The voltage and current curves obtained by simulation with MATLAB SIMULINK are in good conformity with those obtained by experimental of conventional power supply using a single phase transformer for one magnetron. The same curves will allow us to plot the instantaneous power absorbed by each magnetron. This leads to determine the average power emitted by each magnetron, and establish the balance of the power microwave generator by computing its performance which is compared to that obtained from experimental. After that we will compute the power factor of this power supply and we will study its operation in case of failure of one or two magnetrons.

Collaboration network of the authors

18 authors · 57 co-authorship links · 20 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Université Ibn Zohr
  • Mohammed V University
  • International University of Rabat
  • Ecole Mohammadia d'Ingénieurs
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
N. El GhazalUniversité Ibn Zohr7
A. BelhaibaUniversité Ibn Zohr6
Ali BouzitUniversité Ibn Zohr5
Boubkar BahaniUniversité Ibn Zohr4
Reda RabehInternational University of Rabat2
N. ElghazalAffiliation unknown2
M.Ould AhmedouMohammed V University2
Bahani BoubkerAffiliation unknown2
M. FadelUniversité Ibn Zohr2
R. BatitUniversité Ibn Zohr2
Hamid OutzguinrimtUniversité Ibn Zohr2
Mouhcine LahameUniversité Ibn Zohr2
Rajaa OumgharUniversité Ibn Zohr2
Abdessamade BouaddiEcole Mohammadia d'Ingénieurs1
Youssef El BaqqalMohammed V University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A New Validation Approach of  a New Three-Phase High Voltage Power Supply for Microwaves Generators with one Magnetron by Phase</dc:title><dc:creator>Bassoui, M.</dc:creator><dc:creator>Ferfra, M.</dc:creator><dc:creator>Chraygane, M.</dc:creator><dc:description>&lt;jats:p&gt;In order to validating the new three-phase High voltage power supply for microwave generators with one magnetron by phase, this paper presents a new validation approach to evaluate the proposed model with several evaluations. This approach is based on the calculation and measurement of the performance and the power factor of this new three-phase power supply, also the study of the operation of this new system in case of failure. The design of this power supply is composed of new three-phase transformer with magnetic shunt, supplying by phase a voltage doubler cell composed of a capacitor and a diode. Each cell in turn, supplies a single magnetron. In this paper we have presented the new three-phase transformer by its equivalent model; it’s a π  quadruple  model composed  of  storable  inductances  able  to translating the nonlinear saturation phenomena for stabilization of  the  magnetron  current. The voltage and current curves obtained by simulation with MATLAB SIMULINK are in good conformity with those obtained by experimental of conventional power supply using a single phase transformer for one magnetron.&amp;lt;strong&amp;gt; &amp;lt;/strong&amp;gt;The same curves will allow us to plot the instantaneous power absorbed by each magnetron. This leads to determine the average power emitted by each magnetron, and establish the balance of the power microwave generator by computing its performance which is compared to that obtained from experimental. After that we will compute the power factor of this power supply and we will study its operation in case of failure of one or two magnetrons.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i1.pp1-11</dc:identifier><dc:identifier>10.11591/ijece.v6i1.pp1-11</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 1 (2016); 1</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/74/90</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>