Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Performance Measurement of a Compact Generator - Hydro Turbine System

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 5 No. 6 (2015)

DOI
10.11591/ijece.v5i6.pp1252-1261
ISSN
2088-8708, 2088-8708
Published
2015-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This study aims to investigate the characteristic of a compact generator – hydro turbine system. The generator is of permanent magnet type and the turbine operates in a very low head. The integration of the two components is conducted in such a way that simplifies the construction of the conventional turbine generator. The method is by mounting the generator stator to the turbine casing and the permanent magnets are assembled in the perimeter of the turbine blade rotor. This simple construction is approached by making the stator from individual teeth and yoke. The permanent magnet generator (PMG) is designed to produce the nominal power of 300 Watt 50 Hz at 83 rpm of turbine shaft. All components of the integrated turbine- generator are totally immersed in the water stream. The stator has to be hermitic to avoid water entering the spool. Another issue investigated is the influence of the type of the stator inner casing material to the generator performance. The results show, the PVC material for inner casing has a good influence to the generator performance compared with the mild steel material.

Collaboration network of the authors

10 authors · 21 co-authorship links · 6 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • National Research and Innovation Agency
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Anwar MuqorobinIndonesian Institute of Sciences2
Muhammad Fathul HikmawanNational Research and Innovation Agency2
Yugo KumoroIndonesian Institute of Sciences1
Yuliana SusilowatiIndonesian Institute of Sciences1
Wawan Hendriawan NurIndonesian Institute of Sciences1
Yunarto YunartoIndonesian Institute of Sciences1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Performance Measurement of a Compact  Generator - Hydro Turbine System</dc:title><dc:creator>Irasari, Pudji</dc:creator><dc:creator>Sutikno, Priyono</dc:creator><dc:creator>Widiyanto, Puji</dc:creator><dc:creator>Maulana, Qidun</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;This study aims to investigate the characteristic of a compact generator – hydro turbine system. The generator is of permanent magnet type and the turbine operates in a very low head. The integration of the two components is conducted in such a way that simplifies the construction of the conventional turbine generator. The method is by mounting the generator stator to the turbine casing and the permanent magnets are assembled in the perimeter of the turbine blade rotor. This simple construction is approached by making the stator from individual teeth and yoke. The permanent magnet generator (PMG) is designed to produce the nominal power of 300 Watt 50 Hz at 83 rpm of turbine shaft. All components of the integrated turbine- generator are totally immersed in the water stream. The stator has to be hermitic to avoid water entering the spool. Another issue investigated is the influence of the type of the stator inner casing material to the generator performance. The results show, the PVC material for inner casing has a good influence to the generator performance compared with the mild steel material.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2015-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v5i6.pp1252-1261</dc:identifier><dc:identifier>10.11591/ijece.v5i6.pp1252-1261</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 5 No 6 (2015); 1252</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5742/4448</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>