Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Unbalanced Variable Nonlinear Load Compensation Using Multiple Shunt Active Filters

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 5 No. 5 (2015)

DOI
10.11591/ijece.v5i5.pp896-904
ISSN
2088-8708, 2088-8708
Terbit
2015-10-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

The proposed scheme has considered a three-phase four-wire system, which experienced sag and swell in source voltage for a certain period while feeding an unbalanced and variable non-linear load. The load has unequal resistive and reactive elements in the three phases, forming the unbalanced component. A three-phase silicon controlled rectifier converter with adjustable firing angle connected to the load has formed the variable non-linear component. This has been considered, so as to simulate the unbalanced and variable non-linear nature of loads in real-time power system. The trends in the total harmonic distortion variation were obtained for the proposed system under power factor correction and voltage regulation mode operation when the load-side converter firing angles of 30°, 60° and 90° were considered using MATLAB/SIMULINK software. Three pulse-width-modulation methods, namely, sinusoidal pulse-width-modulation, space vector modulation and hysteresis pulse-width-modulation have been used to generate pulses for the voltage source converter of the shunt active filter based on the reference currents generated using synchronous reference frame theory. It has been demonstrated in the proposed paper that power factor correction, voltage regulation, better harmonic reduction and hence load compensation are obtained simultaneously by using two SAFs.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Unbalanced Variable Nonlinear Load Compensation Using Multiple Shunt Active Filters</dc:title><dc:creator>Janyavula, Deepthi</dc:creator><dc:creator>Saxena, Satyendra Nath</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;The proposed scheme has considered a three-phase four-wire system, which experienced sag and swell in source voltage for a certain period while feeding an unbalanced and variable non-linear load. The load has unequal resistive and reactive elements in the three phases, forming the unbalanced component. A three-phase silicon controlled rectifier converter with adjustable firing angle connected to the load has formed the variable non-linear component. This has been considered, so as to simulate the unbalanced and variable non-linear  nature of loads in real-time power system. The trends in the total harmonic distortion variation were obtained for the proposed system under power factor correction and voltage regulation mode operation when the load-side converter firing angles of 30°, 60° and 90° were considered using MATLAB/SIMULINK software. Three pulse-width-modulation methods, namely, sinusoidal pulse-width-modulation, space vector modulation and hysteresis pulse-width-modulation have been used to generate pulses for the voltage source converter of the shunt active filter based on the reference currents generated using synchronous reference frame theory.  It has been demonstrated in the proposed paper that power factor correction, voltage regulation, better harmonic reduction and hence load compensation are obtained simultaneously by using two SAFs.&amp;lt;/span&amp;gt;&amp;lt;br /&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2015-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v5i5.pp896-904</dc:identifier><dc:identifier>10.11591/ijece.v5i5.pp896-904</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 5 No 5 (2015); 896</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5709/4529</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>