Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Fault Location Effect on Short-Circuit Calculations of a TCVR Compensated Line in Algeria

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 5 No. 1 (2015)

DOI
10.11591/ijece.v5i1.pp1-12
ISSN
2088-8708, 2088-8708
Published
2015-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This research work investigated the effect of fault location on short-circuit calculations for a high voltage transmission line equipped with a novel FACTS device, namely Thyristor Controlled Voltage Regulator (TCVR). This main function of this device was to control the voltage and active power of the line. The paper considered a study case for a 220 kV transmission line, in the Algerian transmission power network, which was subjected to a phase to earth fault in the presence of a fixed fault resistance. The paper presented theoretical analysis of the short-circuit calculations which was confirmed by the illustrated simulation results. Simulation results showed the impact of the fault location on the symmetrical current and voltage components of the line, and transmission line phase currents and voltages; before using TCVR and in the presence of TCVR for both cases of positive and negative TCVR controlled voltage.

Collaboration network of the authors

3 authors · 3 co-authorship links · 2 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Batna 1
  • Dhofar University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Fault Location Effect on Short-Circuit Calculations of a TCVR Compensated Line in Algeria</dc:title><dc:creator>Zellagui, Mohamed</dc:creator><dc:creator>Hassan, Heba Ahmed</dc:creator><dc:creator>Chaghi, Abdelaziz</dc:creator><dc:description>&lt;jats:p&gt;This research work investigated the effect of fault location on short-circuit calculations for a high voltage transmission line equipped with a novel FACTS device, namely Thyristor Controlled Voltage Regulator (TCVR). This main function of this device was to control the voltage and active power of the line. The paper considered a study case for a 220 kV transmission line, in the Algerian transmission power network, which was subjected to a phase to earth fault in the presence of a fixed fault resistance. The paper presented theoretical analysis of the short-circuit calculations which was confirmed by the illustrated simulation results. Simulation results showed the impact of the fault location on the symmetrical current and voltage components of the line, and transmission line phase currents and voltages; before using TCVR and in the presence of TCVR for both cases of positive and negative TCVR controlled voltage.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2015-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v5i1.pp1-12</dc:identifier><dc:identifier>10.11591/ijece.v5i1.pp1-12</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 5 No 1 (2015); 1</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/5610/4770</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>