Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Comparison of Ultrasound Image Classification Methods for Benign and Malignant Breast Tumors Based on Texture and Shape Characteristics

Jurnal Fisika · Vol. 16 No. 1 (2026)

DOI
10.15294/jf.v16i1.39242
ISSN
2684-978X, 2088-1509
Terbit
2026-05-15
Penerbit
Universitas Negeri Semarang
Bahasa
eng

Abstrak

Early detection of breast tumors is important to accurately distinguish benign and malignant lesions. This study aims to compare the performance of Random Forest and Naïve Bayes algorithms in the classification of breast ultrasound images based on texture and shape features. The dataset comes from BUSI which consists of two classes: benign 891 images and malignant 421 images, with images through the pre-processing stage, histogram feature extraction, GLCM, as well as morphological features (circularity and elongation). Feature rankings using Relief show that GLCM Homogeneity has the greatest contribution in distinguishing the two classes. Performance evaluation was carried out using K-Fold Cross Validation with variations of K=5, 10, 15, 20, and 25. The results showed that consistently placed Random Forest as the best-performing model. Random Forest achieved the highest accuracy at k-fold-5 at 74.18%, with stable AUC values at 0.771-0.777, sensitivity reaching 78.25%, and better specificity (62-63%) across the fold. In contrast, Naïve Bayes showed lower accuracy with a maximum value of 59% at k-fold-25, AUC in the range of 0.68, and low specificity (42-43%) despite the relatively high sensitivity. These findings confirm that across all k-fold validations, Random Forest remains the most balanced and reliable model for distinguishing benign and malignant in breast.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 25 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Walisongo State Islamic University
  • Sunan Kalijaga State Islamic University Yogyakarta
  • Indonesian Institute of Sciences
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Moch. HusainWalisongo State Islamic University1
Delia Okta RahmadaniWalisongo State Islamic University1
Muhammad Akmal K. HWalisongo State Islamic University1
Alvania Nabila TasyakurantiWalisongo State Islamic University1
Qolby SabrinaIndonesian Institute of Sciences1
Anis YuniatiSunan Kalijaga State Islamic University Yogyakarta1
Bintang RamadhaniSunan Kalijaga State Islamic University Yogyakarta1
Frida Agung RakhmadiSunan Kalijaga State Islamic University Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jf/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Comparison of Ultrasound Image Classification Methods for Benign and Malignant Breast Tumors Based on Texture and Shape Characteristics</dc:title>
	<dc:creator xml:lang="en">Senandung, Nova</dc:creator>
	<dc:creator xml:lang="en">Firdayana, Nanda</dc:creator>
	<dc:creator xml:lang="en">Dewi Anggun Puspita Septiani</dc:creator>
	<dc:creator xml:lang="en">Syahwa Ais Saputri</dc:creator>
	<dc:creator xml:lang="en">Heni Sumarti  </dc:creator>
	<dc:subject xml:lang="en">Breast ultrasound</dc:subject>
	<dc:subject xml:lang="en"> Texture and shape features</dc:subject>
	<dc:subject xml:lang="en">Random Forest</dc:subject>
	<dc:subject xml:lang="en">Naïve Bayes</dc:subject>
	<dc:subject xml:lang="en"> K-fold cross validation</dc:subject>
	<dc:description xml:lang="en">Early detection of breast tumors is important to  accurately distinguish benign and malignant lesions  . This study aims to compare the performance of Random Forest and Naïve Bayes algorithms in the classification of breast ultrasound images based on texture and shape features. The dataset comes from BUSI which consists of two classes: benign 891 images and malignant 421 images, with images through the pre-processing stage, histogram feature extraction, GLCM, as well as morphological features (circularity and elongation). Feature rankings using Relief show that GLCM Homogeneity has the greatest contribution in distinguishing the two classes. Performance evaluation was carried out using K-Fold Cross Validation with  variations of K=5, 10, 15, 20, and 25. The results showed that consistently placed Random Forest as the best-performing model. Random Forest achieved the highest accuracy at k-fold-5 at 74.18%, with stable AUC values at 0.771-0.777, sensitivity reaching 78.25%, and better specificity (62-63%) across the fold. In contrast, Naïve Bayes showed lower accuracy with a maximum value of 59% at k-fold-25, AUC in the range of 0.68, and low specificity (42-43%) despite the relatively high sensitivity. These findings confirm that across all k-fold validations, Random Forest remains the most balanced and reliable model for distinguishing benign and malignant in breast.</dc:description>
	<dc:publisher xml:lang="en">Universitas Negeri Semarang</dc:publisher>
	<dc:date>2026-05-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/jf/article/view/39242</dc:identifier>
	<dc:identifier>10.15294/jf.v16i1.39242</dc:identifier>
	<dc:source xml:lang="en">Jurnal Fisika; Vol. 16 No. 1 (2026): Jurnal Fisika 16 (1) 2026</dc:source>
	<dc:source>2684-978X</dc:source>
	<dc:source>2088-1509</dc:source>
	<dc:source>10.15294/jf.v16i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/jf/article/view/39242/9691</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Jurnal Fisika</dc:rights>
</oai_dc:dc>