Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Optimal unit commitment of a power plant using particle swarm optimization approach

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 2 (2020)

DOI
10.11591/ijece.v10i2.pp1135-1141
ISSN
2088-8708, 2088-8708
Published
2020-04-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Economic load dispatch among generating units is very important for any power plant. In this work, the economic load dispatch was made at Egbin Thermal Power plant supplying a total load of 600MW using six generating units. In carrying out this study, transmission losses were assumed to be included into the load supplied. Also three different combinations in the form of 6, 5 and 4 units commitment were considered. In each case, the total load was optimally dispatched between committed generating units using Particle Swarm Optimization (PSO). Similarly, the generation cost for each generating unit was determined. For case 1, the six generators were committed and the generation cost is 2,100,685.069$/h. For case 2, five generators were committed and the generation cost is 2,520,861.947$/h. For case 3, four generators were committed and the generation cost is 3,150,621.685$/h. From all considered cases, it was found that, the minimum generation cost was achieved when all six generating units were committed and a total of 420,178.878$/h was saved.

Collaboration network of the authors

8 authors · 16 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Nigeria
  • Enugu State University of Science and Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Princewill C. EneEnugu State University of Science and Technology2
Amanze C. FortuneUniversity of Nigeria2
Luke Uwakwe OmejeUniversity of Nigeria2
Innocent Onyebuchi OziokoUniversity of Nigeria1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Optimal unit commitment of a power plant using particle swarm optimization approach</dc:title><dc:creator>Anyaka, Boniface O.</dc:creator><dc:creator>Manirakiza, J. Felix</dc:creator><dc:creator>Chike, Kenneth C.</dc:creator><dc:creator>Okoro, Prince A.</dc:creator><dc:description>&lt;jats:p&gt;Economic load dispatch among generating units is very important for any power plant. In this work, the economic load dispatch was made at Egbin Thermal Power plant supplying a total load of 600MW using six generating units. In carrying out this study, transmission losses were assumed to be included into the load supplied. Also three different combinations in the form of 6, 5 and 4 units commitment were considered. In each case, the total load was optimally dispatched between committed generating units using Particle Swarm Optimization (PSO).  Similarly, the generation cost for each generating unit was determined. For case 1, the six generators were committed and the generation cost is 2,100,685.069$/h. For case 2, five generators were committed and the generation cost is 2,520,861.947$/h. For case 3, four generators were committed and the generation cost is 3,150,621.685$/h. From all considered cases, it was found that, the minimum generation cost was achieved when all six generating units were committed and a total of 420,178.878$/h was saved.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i2.pp1135-1141</dc:identifier><dc:identifier>10.11591/ijece.v10i2.pp1135-1141</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 2 (2020); 1135</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/16946/pdf</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>