Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Binary operation based hard exudate detection and fuzzy based classification in diabetic retinal fundus images for real time diagnosis applications

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 3 (2020)

DOI
10.11591/ijece.v10i3.pp2305-2312
ISSN
2088-8708, 2088-8708
Terbit
2020-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

Diabetic retinopathy (DR) is one of the most considerable reasons for visual impairment. The main objective of this paper is to automatically detect and recognize DR lesions like hard exudates, as it helps in diagnosing and screening of the disease. Here, binary operation based image processing for detecting lesions and fuzzy logic based extraction of hard exudates on diabetic retinal images are discused. In the initial stage, the binary operations are used to identify the exudates. Similarly, the RGB channel space of the DR image is used to create fuzzy sets and membership functions for extracting the exudates. The membership directives obtained from the fuzzy rule set are used to detect the grade of exudates. In order to evaluate the proposed approach, experiment tests are carriedout on various set of images and the results are verified. From the experiment results, the sensitivity obtained is 98.10%, specificity is 96.96% and accuracy is 98.2%. These results suggest that the proposed method could be a diagnostic aid for ophthalmologists in the screening for DR.

Jaringan kolaborasi para penulis

7 penulis · 16 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Noorul Islam University
  • Bule Hora University
  • Jawaharlal Nehru Technological University Anantapur
  • Sengunthar Engineering College (Autonomous)
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Eugine Prince MAfiliasi tidak diketahui1
M. D. VijayakumarJawaharlal Nehru Technological University Anantapur1
P. Sujatha ThereseNoorul Islam University1
P. Josephin ShermilaAfiliasi tidak diketahui1
Maris Murugan TSengunthar Engineering College (Autonomous)1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Binary operation based hard exudate detection and fuzzy based classification in diabetic retinal fundus images for real time diagnosis applications</dc:title><dc:creator>Pradeep, Arun</dc:creator><dc:creator>Joseph, X Felix</dc:creator><dc:description>&lt;jats:p&gt;Diabetic retinopathy (DR) is one of the most considerable reasons for visual impairment. The main objective of this paper is to automatically detect and recognize DR lesions like hard exudates, as it helps in diagnosing and screening of the disease. Here, binary operation based image processing for detecting lesions and fuzzy logic based extraction of hard exudates on diabetic retinal images are discused. In the initial stage, the binary operations are used to identify the exudates. Similarly, the RGB channel space of the DR image is used to create fuzzy sets and membership functions for extracting the exudates. The membership directives obtained from the fuzzy rule set are used to detect the grade of exudates. In order to evaluate the proposed approach, experiment tests are carriedout on various set of images and the results are verified. From the experiment results, the sensitivity obtained is 98.10%, specificity is 96.96% and accuracy is 98.2%.  These results suggest that the proposed method could be a diagnostic aid for ophthalmologists in the screening for DR.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i3.pp2305-2312</dc:identifier><dc:identifier>10.11591/ijece.v10i3.pp2305-2312</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 3 (2020); 2305</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/20001/pdf</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>