Abstract

In this paper, A novel modified optimization method was used to find the optimal location and size for placing distribution Static Compensator in the radial distribution test feeder in order to improve its performance by minimizing the total power losses of the test feeder, enhancing the voltage profile and reducing the costs. The modified grey wolf optimization algorithm is used for the first time to solve this kind of optimization problem. An objective function was developed to study the radial distribution system included total power loss of the system and costs due to power loss in system. The proposed method is applied to two different test distribution feeders (33 bus and 69 bus test systems) using different Dstatcom sizes and the acquired results were analyzed and compared to other recent optimization methods applied to the same test feeders to ensure the effectiveness of the used method and its superiority over other recent optimization mehods. The major findings from obtained results that the applied technique found the most minimized total power loss in system,the best improved voltage profile and most reduction in costs due power loss compared to other methods.

Collaboration network of the authors

13 authors · 26 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Ain Shams University
  • The Future University
  • Princess Nourah bint Abdulrahman University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hossam E. A. TalaatThe Future University4
M. M. H. ElrobyAin Shams University3
M. A. Moustafa HassanAffiliation unknown2
Nesreen S. HosnyAffiliation unknown2
Shimaa Aly HussienPrincess Nourah bint Abdulrahman University2
M. EL-AzabAin Shams University1
Walid Atef OmranAin Shams University1
M. A. Moustafa HassanAffiliation unknown1
Ramy M. HossamAin Shams University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhancing radial distribution system performance by optimal placement of DSTATCOM</dc:title><dc:creator>Mekhamer, S. F.</dc:creator><dc:creator>Shehata, R. H.</dc:creator><dc:creator>Abdelaziz, A. Y.</dc:creator><dc:creator>Al-Gabalawy, M. A.</dc:creator><dc:description>&lt;jats:p&gt;In this paper, A novel modified optimization method  was used to find &#xD;
the optimal location and size for placing distribution Static Compensator in the radial distribution test feeder in order to improve its performance by minimizing the total power losses of the test feeder, enhancing the voltage profile and reducing the costs. The modified grey wolf optimization algorithm is used for the first time to solve this kind of optimization problem. An objective function was developed to study the radial distribution system included total power loss of the system and costs due to power loss in system. The proposed method is applied to two different test distribution feeders (33 bus and 69 bus test systems) using different Dstatcom sizes and the acquired results were analyzed and compared to other recent optimization methods applied to the same test feeders to ensure the effectiveness of &#xD;
the used method and its superiority over other recent optimization mehods. The major findings from obtained results that the applied technique found &#xD;
the most minimized total power loss in system ,the best  improved voltage profile and most reduction in costs due power loss compared to other methods&#xD;
.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i3.pp2850-2860</dc:identifier><dc:identifier>10.11591/ijece.v10i3.pp2850-2860</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 3 (2020); 2850</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/20343/pdf</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>