Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

An enhanced lossless compression with cryptography hybrid mechanism for ECG biomedical signal monitoring

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 3 (2020)

DOI
10.11591/ijece.v10i3.pp3235-3243
ISSN
2088-8708, 2088-8708
Published
2020-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Due to their use in daily life situation, demand for remote health applications and e-health monitoring equipment is growing quickly. In this phase, for fast diagnosis and therapy, information can be transferred from the patient to the distant clinic. Nowadays, the most chronic disease is cardiovascular diseases (CVDs). However, the storage and transmission of the ECG signal, consumes more energy, bandwidth and data security which is faced many challenges. Hence, in this work, we present a combined approach for ECG data compression and cryptography. The compression is performed using adaptive Huffman encoding and encrypting is done using AES (CBC) scheme with a 256-bit key. To increase the security, we include Diffie-Hellman Key exchange to authenticate the receiver, RSA key generation for encrypting and decrypting the data. Experimental results show that the proposed approach achieves better performance in terms of compression and encryption on MIT-BIH ECG dataset.

Collaboration network of the authors

21 authors · 54 co-authorship links · 18 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Islam Melaka
  • University of Sumer
  • University of Diyala
  • University of Babylon
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Mothana Lafta AttiahUniversiti Teknikal Malaysia Melaka3
Ali Hameed YassirUniversity of Sumer2
Adel Abdul-Jabbar AlkhazrajiUniversity of Diyala2
Mohammed Saad TalibUniversity of Babylon2
Mohanad Faeq AliUniversiti Teknikal Malaysia Melaka2
Ahmad Fauzan KadminUniversiti Teknikal Malaysia Melaka1
Rostam Affendi HamzahUniversiti Teknikal Malaysia Melaka1
Mohd SaadUniversiti Teknikal Malaysia Melaka1
Nadzrie NadzrieUniversiti Teknikal Malaysia Melaka1
Tg. Mohd FaisalUniversiti Teknikal Malaysia Melaka1
M. A. BurhanuddinUniversiti Teknikal Malaysia Melaka1
Ronizam IsmailUniversiti Islam Melaka1
Nurul IzzaimahUniversiti Islam Melaka1
Norzaimah ZainolUniversiti Teknikal Malaysia Melaka1
A. M. DarsonoUniversiti Teknikal Malaysia Melaka1
C. C. TohUniversiti Teknikal Malaysia Melaka1
Nik Mohd Zarifie HashimUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>An enhanced lossless compression with cryptography hybrid mechanism for ECG biomedical signal monitoring</dc:title><dc:creator>Hameed, Mustafa</dc:creator><dc:creator>Ibrahim, Masrullizam Mat</dc:creator><dc:creator>Manap, Nurulfajar Abd</dc:creator><dc:creator>Mohammed, Ali A.</dc:creator><dc:description>&lt;jats:p&gt;Due to their use in daily life situation, demand for remote health applications and e-health monitoring equipment is growing quickly. In this phase, for fast diagnosis and therapy, information can be transferred from the patient to the distant clinic. Nowadays, the most chronic disease is cardiovascular diseases (CVDs). However, the storage and transmission of the ECG signal, consumes more energy, bandwidth and data security which is faced many challenges. Hence, in this work, we present a combined approach for ECG data compression and cryptography. The compression is performed using adaptive Huffman encoding and encrypting is done using AES (CBC) scheme with a 256-bit key. To increase the security, we include Diffie-Hellman Key exchange to authenticate the receiver, RSA key generation for encrypting and decrypting the data. Experimental results show that the proposed approach achieves better performance in terms of compression and encryption on MIT-BIH ECG dataset.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i3.pp3235-3243</dc:identifier><dc:identifier>10.11591/ijece.v10i3.pp3235-3243</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 3 (2020); 3235</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/20792/pdf</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>