Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Analysis of direct power control AC-DC converter under unbalance voltage supply for steady-state and dynamic response

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 4 (2020)

DOI
10.11591/ijece.v10i4.pp3333-3342
ISSN
2722-2578, 2088-8708
Published
2020-08-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper presents an analysis of Direct Power Control (DPC) technique for the Three-Phase Pulse Width Modulation (PWM) AC-DC converter under unbalanced supply condition. Unbalance condition will cause the presence of unbalanced current and voltages thus produce the negative components on the grid voltage as well as severe performance degradation of a grid connected Voltage Source Inverter (VSI). The input structures for conventional DPC has been modified with a three simpler sequence networks instead of coupled by a detailed Three-Phase system method. The imbalance voltage can be resolved by separating from the individual elements of voltage and current into symmetrical components called Sequence Network. Consequently, the input power relatively improved during unbalanced condition almost 70% through the measurement of Total Harmonic Distortion (THD) from the conventional Direct Power Control (DPC) in individual elements which is higher compared to separate components. Hence, several analyses are performed in order to analyze the steady state and dynamic performance of the converter, particularly during the load and DC voltage output reference variations.

Collaboration network of the authors

20 authors · 51 co-authorship links · 18 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Tun Hussein Onn University of Malaysia
  • Universiti Sains Malaysia
  • Universitas Ahmad Dahlan
  • University of Technology Malaysia
  • Universiti Malaysia Perlis
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Tole SutiknoUniversitas Ahmad Dahlan3
T. C. KwangUniversiti Teknikal Malaysia Melaka2
Mohd Luqman Mohd Jamil‬Universiti Teknikal Malaysia Melaka2
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka1
Nik Rumzi Nik IdrisUniversity of Technology Malaysia1
Mohd Firdaus Mohd Ab HalimUniversiti Teknikal Malaysia Melaka1
Erwan SulaimanAffiliation unknown1
Mahyuzie JenalTun Hussein Onn University of Malaysia1
Syed Muhammad Naufal Syed OthmanTun Hussein Onn University of Malaysia1
Muhammad Zaid AihsanUniversiti Malaysia Perlis1
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka1
Muhammad Hafeez Mohamed HaririUniversiti Sains Malaysia1
Lim Kean BoonUniversiti Sains Malaysia1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Analysis of direct power control AC-DC converter under unbalance voltage supply for steady-state and dynamic response</dc:title><dc:creator>Mohd Yusoff, Nor Azizah</dc:creator><dc:creator>Razali, Azziddin M.</dc:creator><dc:creator>Karim, Kasrul Abdul</dc:creator><dc:creator>Raja Othman, Raja Nor Firdaus Kashfi</dc:creator><dc:creator>Jidin, Auzani</dc:creator><dc:creator>Md Zuki, Nor Aishah</dc:creator><dc:creator>Abdullah, Nurfaezah</dc:creator><dc:description>&lt;jats:p&gt;This paper presents an analysis of Direct Power Control (DPC) technique for the Three-Phase Pulse Width Modulation (PWM) AC-DC converter under unbalanced supply condition. Unbalance condition will cause the presence of unbalanced current and voltages thus produce the negative components on the grid voltage as well as severe performance degradation of a grid connected Voltage Source Inverter (VSI). The input structures for conventional DPC has been modified with a three simpler sequence networks instead of coupled by a detailed Three-Phase system method. The imbalance voltage can be resolved by separating from the individual elements of voltage and current into symmetrical components called Sequence Network. Consequently, the input power relatively improved during unbalanced condition almost 70% through the measurement of Total Harmonic Distortion (THD) from the conventional Direct Power Control (DPC) in individual elements which is higher compared to separate components. Hence, several analyses are performed in order to analyze the steady state and dynamic performance of the converter, particularly during the load and DC voltage output reference variations.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i4.pp3333-3342</dc:identifier><dc:identifier>10.11591/ijece.v10i4.pp3333-3342</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 4 (2020); 3333</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/21488/13966</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>