Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The electromagnetic interferance caused by high voltage power lines along the electrical railway equipment

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 5 (2020)

DOI
10.11591/ijece.v10i5.pp4581-4591
ISSN
2722-2578, 2088-8708
Terbit
2020-10-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

The identification of risks linked to electromagnetic compatibility (EMC) in the electric railway is a major concern in identifying EMC problems and analyzing the unintentional various external disturbing sources as well as the probability of occurrence of interference, the level of interference along the railway system. The purpose of this analysis is to determine the electromagnetic interaction coupling generated by the high voltage (HV) lines located along the railway line by analyzing the voltage induced in the signaling transmission cables such as the European rail traffic management system/European train control system (ERTMS/ETCS) through the multi-conductor transmission line (MTL) theory which may have an impact on the transmitting information. Dubanton method and approximate calculation will be applied and simulated through COMSOL Multiphysics tool in order to analyze if the protection distance and coupling conditions are respected by the railway standards.

Jaringan kolaborasi para penulis

20 penulis · 36 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Ecole Mohammadia d'Ingénieurs
  • Université Moulay Ismail de Meknes
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kaoutar RabyiMohammed V University2
Anass BakouriMohammed V University2
Marouane El AzzaouiMohammed V University2
Naoufal ZhaniMohammed V University1
Chafik Ed-dahmaniUniversité Moulay Ismail de Meknes1
Sana SahbaniMohammed V University1
Abdennebi El HasnaouiAfiliasi tidak diketahui1
Mustapha KchikachAfiliasi tidak diketahui1
Hanane BenchraaMohammed V University1
Ilham RaisMohammed V University1
Karima BoudaraiaEcole Mohammadia d'Ingénieurs1
Ahmed AbbouMohammed V University1
Abdelaali OuhammamAfiliasi tidak diketahui1
Youssef El HachimiAfiliasi tidak diketahui1
Amina DaghouriAfiliasi tidak diketahui1
Abdennebi El HassnaouiAfiliasi tidak diketahui1
Nabil QachchachiEcole Mohammadia d'Ingénieurs1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>The electromagnetic interferance caused by high voltage power lines along the electrical railway equipment</dc:title><dc:creator>El Hajji, Moine</dc:creator><dc:creator>Mahmoudi, Hassane</dc:creator><dc:creator>Labbadi, Moussa</dc:creator><dc:description>&lt;jats:p&gt;The identification of risks linked to electromagnetic compatibility (EMC) in the electric railway is a major concern in identifying EMC problems and analyzing the unintentional various external disturbing sources as well as the probability of occurrence of interference, the level of interference along the railway system. The purpose of this analysis is to determine the electromagnetic interaction coupling generated by the high voltage (HV) lines located along the railway line by analyzing the voltage induced in the signaling transmission cables such as the European rail traffic management system/European train control system (ERTMS/ETCS) through the multi-conductor transmission line (MTL) theory which may have an impact on the transmitting information. Dubanton method and approximate calculation will be applied and simulated through COMSOL Multiphysics tool in order to analyze if the protection distance and coupling conditions are respected by the railway standards.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i5.pp4581-4591</dc:identifier><dc:identifier>10.11591/ijece.v10i5.pp4581-4591</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 5 (2020); 4581</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/21415/14166</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>