Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Modified sub-gradient based combined objective technique and evolutionary programming approach for economic dispatch involving valve-point loading, enhanced prohibited zones and ramp rate constraints

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 5 (2020)

DOI
10.11591/ijece.v10i5.pp5048-5057
ISSN
2722-2578, 2088-8708
Published
2020-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

A security constrained non-convex power dispatch problem with prohibited operation zones and ramp rates is formulated and solved using an iterative solution method based on the feasible modified sub-gradient algorithm (FMSG). Since the cost function, all equality and inequality constraints in the nonlinear optimization model are written in terms of the bus voltage magnitudes, phase angles, off-nominal tap settings, and the Susceptance values of static VAR (SVAR) systems, they can be taken as independent variables. The actual power system loss is included in the current approach and the load flow equations are inserted into the model as the equality constraints. The proposed modified sub gradient based combined objective technique and evolutionary programming approach (MSGBCAEP) with as decision variable and cost function as fitness function is tested on the IEEE 30-bus 6 generator test case system. The absence of crossover operation and adoption of fast judicious modifications in initialization of parent population, offspring generation and normal distribution curve selection in EP enables the proposed MSGBCAEP approach to ascertain global optimal solution for cost of generation and emission level shown in Table 6 and displayed in Figure 2 and Figure 3 respectively.

Collaboration network of the authors

6 authors · 8 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Biju Patnaik University of Technology
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Banalata Priyadarshani DeoBiju Patnaik University of Technology2
Saroj Kumar DashAffiliation unknown1
Ray PriyambadaBiju Patnaik University of Technology1
Himanshu Shekhar MaharanaBiju Patnaik University of Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Modified sub-gradient based combined objective technique and evolutionary programming approach for economic dispatch involving valve-point loading, enhanced prohibited zones and ramp rate constraints</dc:title><dc:creator>Gachhayat, Susanta Kumar</dc:creator><dc:creator>Dash, Saroja Kumar</dc:creator><dc:description>&lt;jats:p&gt;A security constrained non-convex power dispatch problem with prohibited operation zones and ramp rates is formulated and solved using an iterative solution method based on the feasible modified sub-gradient algorithm (FMSG). Since the cost function, all equality and inequality constraints in the nonlinear optimization model are written in terms of the bus voltage magnitudes,  phase angles,  off-nominal tap settings, and the Susceptance values of static VAR (SVAR) systems, they can be taken as independent variables. The actual power system loss is included in the current approach and the load flow equations are inserted into the model as the equality constraints. The proposed modified sub gradient based combined objective technique and evolutionary programming approach (MSGBCAEP) with  as decision variable and cost function as fitness function is tested on the IEEE 30-bus 6 generator test case   system. The absence of crossover operation and adoption of fast judicious modifications in initialization of parent population, offspring generation and normal distribution curve selection in EP enables the proposed MSGBCAEP approach to ascertain global optimal solution for cost of generation and emission level shown in Table 6 and displayed in Figure 2 and Figure 3  respectively.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i5.pp5048-5057</dc:identifier><dc:identifier>10.11591/ijece.v10i5.pp5048-5057</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 5 (2020); 5048</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/21485/14227</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>