Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Rotor Angle Analysis on Power Proportion in Generator and Photovoltaic Hybrid Low Voltage System

Jurnal Teknik Elektro · Vol. 16 No. 1 (2024)

DOI
10.15294/jte.v16i1.3074
ISSN
2549-1571, 1411-0059
Terbit
2024-06-30
Penerbit
LPPM Universitas Negeri Semarang
Bahasa
eng

Abstrak

Electrical energy is essential in modern society, and with the growing demand, all available energy resources are being utilized to meet this need. Insufficient planning and calculation in energy provision can affect the stability of electricity generated by power plants, especially in low-voltage microsystems directly connected to loads. This study investigates the behavior of synchronous microgenerators and photovoltaic systems, focusing on the rotor angle of the generator. Changes in the photovoltaic contribution can cause shifts in the generator's rotor angle, necessitating an analysis of these shifts. An experimental method was used to measure and analyze the power distribution by recording current and voltage in a micro synchronous generator and a grid-tie inverter under a 300-watt linear load. The results show that the generator’s rotor angle remains stable and the grid-tie inverter remains synchronized, with an average angle of 40.2° at a photovoltaic contribution of 32.26% and a synchronous microgenerator contribution of 67.74%. However, when the photovoltaic supply exceeds 37.00%, the rotor angle shifts further, leading to a loss of synchronization in the grid-tie inverter. Additionally, irradiance was found to have a linear effect on photovoltaic distribution. The findings of this study contribute to a better understanding of rotor angle behavior and grid synchronization, providing insights for the development of more reliable and efficient renewable energy systems that maintain electrical stability in low-voltage applications.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 78 tautan kepenulisan bersama · 39 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • Universitas Ahmad Dahlan
  • Sultan Agung Islamic University
  • SRM Institute of Science and Technology
  • State University of Semarang
  • Universiti Tenaga Nasional
  • Universiti Teknikal Malaysia Melaka
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan6
Watra ArsadiandoAfiliasi tidak diketahui2
Hendril Satrian PurnamaAfiliasi tidak diketahui2
Wahyu Sapto AjiUniversitas Ahmad Dahlan2
Teguh Budi PrakosoDiponegoro University1
Muhammad ZainuriDiponegoro University1
Sudjadi SudjadiDiponegoro University1
Emak Pancar SaktiDiponegoro University1
Auzani JidinUniversiti Teknikal Malaysia Melaka1
Preethicaa RameshSRM Institute of Science and Technology1
Sowmmiya USRM Institute of Science and Technology1
Vigna K. RamachandaramurthyUniversiti Tenaga Nasional1
Chee Wei TanUniversity of Technology Malaysia1
Tri WahonoUniversitas Ahmad Dahlan1
Lina HandayaniUniversitas Ahmad Dahlan1
Sarwo TurinnoDiponegoro University1
Cahyadi CahyadiNational Research and Innovation Agency1
Zainal SalamAfiliasi tidak diketahui1
Munawar Agus RiyadiDiponegoro University1
Imam Much Ibnu SubrotoSultan Agung Islamic University1
Arief MarwantoSultan Agung Islamic University1
Gunawan GunawanSultan Agung Islamic University1
Hermawan HermawanDiponegoro University1
Riza Arif PratamaUniversitas Tunas Pembangunan1
Nur IksanState University of Semarang1
Abdul SyakurDiponegoro University1
Anindira Listy HartisaState University of Semarang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Rotor Angle Analysis on Power Proportion in Generator and Photovoltaic Hybrid Low Voltage System</dc:title>
	<dc:creator xml:lang="en">Prastiyo, Fredi</dc:creator>
	<dc:creator xml:lang="en">Mochammad Facta</dc:creator>
	<dc:creator xml:lang="en">Susatyo Handoko</dc:creator>
	<dc:subject xml:lang="en">electrical systems</dc:subject>
	<dc:subject xml:lang="en">generator rotor angle</dc:subject>
	<dc:subject xml:lang="en">hybrid electric power proportion</dc:subject>
	<dc:subject xml:lang="en">micro generator</dc:subject>
	<dc:subject xml:lang="en">photovoltaic</dc:subject>
	<dc:description xml:lang="en">Electrical energy is essential in modern society, and with the growing demand, all available energy resources are being utilized to meet this need. Insufficient planning and calculation in energy provision can affect the stability of electricity generated by power plants, especially in low-voltage microsystems directly connected to loads. This study investigates the behavior of synchronous microgenerators and photovoltaic systems, focusing on the rotor angle of the generator. Changes in the photovoltaic contribution can cause shifts in the generator's rotor angle, necessitating an analysis of these shifts. An experimental method was used to measure and analyze the power distribution by recording current and voltage in a micro synchronous generator and a grid-tie inverter under a 300-watt linear load. The results show that the generator’s rotor angle remains stable and the grid-tie inverter remains synchronized, with an average angle of 40.2° at a photovoltaic contribution of 32.26% and a synchronous microgenerator contribution of 67.74%. However, when the photovoltaic supply exceeds 37.00%, the rotor angle shifts further, leading to a loss of synchronization in the grid-tie inverter. Additionally, irradiance was found to have a linear effect on photovoltaic distribution. The findings of this study contribute to a better understanding of rotor angle behavior and grid synchronization, providing insights for the development of more reliable and efficient renewable energy systems that maintain electrical stability in low-voltage applications.</dc:description>
	<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
	<dc:date>2024-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/3074</dc:identifier>
	<dc:identifier>10.15294/jte.v16i1.3074</dc:identifier>
	<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 16 No. 1 (2024)</dc:source>
	<dc:source>2549-1571</dc:source>
	<dc:source>1411-0059</dc:source>
	<dc:source>10.15294/j4wyz794</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/3074/8147</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>