In Indonesia, electricity is a basic need with demand that continues to grow. PT PLN (Persero) projects an increase in electricity consumption of 8.9% by early 2022, highlighting the urgent need to address frequent problems such as blackouts, power losses, and voltage sags in the power distribution system. Effective solutions, including Static VAR Compensator (SVC) and Distributed Generation (DG), have been proposed to improve voltage stability and reduce power losses. This study evaluates and compares the performance of SVC and DG on a standard IEEE 14-bus system under increased load conditions. Using power flow analysis in ETAP, we simulate the installation of SVC at 15.99 Mvar and DG at 20.58 Mvar on bus 9, which shows optimal results. The findings show that DG slightly outperforms SVC in improving voltage stability and reducing power losses, with a 0.16% greater voltage increase and a 3.2 MW or 17.3% reduction in power losses. These results indicate that although both devices meet PLN’s voltage standards and improve power system efficiency, DG provides a slightly superior improvement in overall system performance.
Jaringan kolaborasi para penulis
7 penulis ·
12 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Islam Negeri Sultan Syarif Kasim Riau Universitas Lancang Kuning National University of Malaysia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Comparative Analysis of Static Var Compensator and Distributed Generation Installation on Voltage Profile</dc:title>
<dc:creator xml:lang="en">Zulfatri Aini</dc:creator>
<dc:creator xml:lang="en">Guido, Muhammad Guido Randa Febiant</dc:creator>
<dc:creator xml:lang="en">Tengku Reza Suka Alaqsa</dc:creator>
<dc:creator xml:lang="en">Liliana</dc:creator>
<dc:subject xml:lang="en">SVC</dc:subject>
<dc:subject xml:lang="en">DG</dc:subject>
<dc:subject xml:lang="en">Voltage</dc:subject>
<dc:subject xml:lang="en">Electrical System</dc:subject>
<dc:subject xml:lang="en">Voltage Drop</dc:subject>
<dc:description xml:lang="en">In Indonesia, electricity is a basic need with demand that continues to grow. PT PLN (Persero) projects an increase in electricity consumption of 8.9% by early 2022, highlighting the urgent need to address frequent problems such as blackouts, power losses, and voltage sags in the power distribution system. Effective solutions, including Static VAR Compensator (SVC) and Distributed Generation (DG), have been proposed to improve voltage stability and reduce power losses. This study evaluates and compares the performance of SVC and DG on a standard IEEE 14-bus system under increased load conditions. Using power flow analysis in ETAP, we simulate the installation of SVC at 15.99 Mvar and DG at 20.58 Mvar on bus 9, which shows optimal results. The findings show that DG slightly outperforms SVC in improving voltage stability and reducing power losses, with a 0.16% greater voltage increase and a 3.2 MW or 17.3% reduction in power losses. These results indicate that although both devices meet PLN’s voltage standards and improve power system efficiency, DG provides a slightly superior improvement in overall system performance.</dc:description>
<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
<dc:date>2024-06-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/8824</dc:identifier>
<dc:identifier>10.15294/jte.v16i1.8824</dc:identifier>
<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 16 No. 1 (2024)</dc:source>
<dc:source>2549-1571</dc:source>
<dc:source>1411-0059</dc:source>
<dc:source>10.15294/j4wyz794</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/8824/8148</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2024 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Aini, Z., Guido, M. G. R. F., Alaqsa, T. R. S., & Liliana (2024). Comparative Analysis of Static Var Compensator and Distributed Generation Installation on Voltage Profile. Jurnal Teknik Elektro, 16(1). https://doi.org/10.15294/jte.v16i1.8824
Salin
IEEE
Z. Aini, M. G. R. F. Guido, T. R. S. Alaqsa, and Liliana, “Comparative Analysis of Static Var Compensator and Distributed Generation Installation on Voltage Profile,” Jurnal Teknik Elektro, vol. 16, no. 1, 2024, doi: 10.15294/jte.v16i1.8824.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.