This study evaluates the financial viability of grid-connected rooftop photovoltaic (PV) systems across seven Indonesian residential types (2.75-19.8 kWp) under current market conditions. Using a discounted cash flow model with 8% discount rate and a 20-year project lifetime, key metrics including Net Present Value (NPV), Levelized Cost of Electricity (LCOE), and payback period have been analysed. Results demonstrate that system economics improve significantly with scale: while small systems (2.75 kWp) yield negative NPV (-Rp 9.71 million) and 12.4-year payback, larger installations (>7.7 kWp) achieve positive NPV (up to Rp 89.95 million for 19.8 kWp systems) and sub-10-year payback periods. The LCOE ranges from Rp 1,082-1,205/kWh, representing 11-36% cost savings compared to PLN's tiered tariffs (Rp 1,352-1,699.53/kWh). Monthly savings scale proportionally with system size, from Rp 323,378 (2.75 kWp) to Rp 2.84 million (19.8 kWp). A critical 7.7 kWp capacity threshold emerges for self-sustaining viability without subsidies, with 3500+ VA customers benefiting most due to higher avoided tariffs. These findings provide policymakers with evidence to design tiered incentive programs targeting underperforming market segments (<6 kWp systems), while confirming the commercial readiness of larger residential-commercial hybrid systems in Indonesia's solar transition.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Trisakti
  • National Research and Innovation Agency
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Techno-Economic of Rooftop Solar Power Plants for Residential Customer in Indonesia</dc:title>
	<dc:creator xml:lang="en">Putri, Dianing Novita Nurmala</dc:creator>
	<dc:creator xml:lang="en">Fariz Maulana Rizanulhaq </dc:creator>
	<dc:creator xml:lang="en">Tyas Kartika Sari</dc:creator>
	<dc:creator xml:lang="en">Maula Sukma Widjaja</dc:creator>
	<dc:creator xml:lang="en">Chairul Gagarin Irianto</dc:creator>
	<dc:subject xml:lang="en">Rooftop Photovoltaic, Techno-Economic, Solar power Plant</dc:subject>
	<dc:description xml:lang="en">This study evaluates the financial viability of grid-connected rooftop photovoltaic (PV) systems across seven Indonesian residential types (2.75-19.8 kWp) under current market conditions. Using a discounted cash flow model with 8% discount rate and a 20-year project lifetime, key metrics including Net Present Value (NPV), Levelized Cost of Electricity (LCOE), and payback period have been analysed. Results demonstrate that system economics improve significantly with scale: while small systems (2.75 kWp) yield negative NPV (-Rp 9.71 million) and 12.4-year payback, larger installations (&amp;gt;7.7 kWp) achieve positive NPV (up to Rp 89.95 million for 19.8 kWp systems) and sub-10-year payback periods. The LCOE ranges from Rp 1,082-1,205/kWh, representing 11-36% cost savings compared to PLN's tiered tariffs (Rp 1,352-1,699.53/kWh). Monthly savings scale proportionally with system size, from Rp 323,378 (2.75 kWp) to Rp 2.84 million (19.8 kWp). A critical 7.7 kWp capacity threshold emerges for self-sustaining viability without subsidies, with 3500+ VA customers benefiting most due to higher avoided tariffs. These findings provide policymakers with evidence to design tiered incentive programs targeting underperforming market segments (&amp;lt;6 kWp systems), while confirming the commercial readiness of larger residential-commercial hybrid systems in Indonesia's solar transition.</dc:description>
	<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
	<dc:date>2024-12-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/14514</dc:identifier>
	<dc:identifier>10.15294/jte.v16i2.14514</dc:identifier>
	<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 16 No. 2 (2024)</dc:source>
	<dc:source>2549-1571</dc:source>
	<dc:source>1411-0059</dc:source>
	<dc:source>10.15294/jte.v16i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/14514/5332</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2024 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>