Skin diseases are among the most common health issues in domestic cats. However, access to veterinarians is often limited, especially in low-resource settings. Automated image-based detection offers a fast and affordable alternative for early intervention. This paper presents a lightweight approach for diagnosing feline skin diseases using EfficientNetV2 optimized for low-resource devices. A balanced custom dataset consisting of 720 images across nine classes, namely Healthy, Mild/Severe Ringworm, Mild/Severe Acne, Mild/Severe Flea, and Mild/Severe Scabies, was compiled from Kaggle, Roboflow, and Google Images, ensuring ethical use of publicly available data. The images were augmented through rotations (0°, 90°, 180°, 270°) and horizontal flips, resulting in 5,760 images, to enhance model generalization. Five CNN architectures were benchmarked: DenseNet121, MobileNetV2, MobileNetV3, EfficientNetB0, and EfficientNetV2B0. Training was conducted with grid searches over batch sizes {64, 32, 16, 8} and learning rates {1e-3, 5e-4, 2e-4, 1e-4, 5e-5} for up to 300 epochs, and with the Adam optimizer and Reduce-LR-on-Plateau (decay factor 0.5). Early stopping (patience = 10) was used to mitigate overfitting. The best model was selected based on highest validation accuracy. The experiments were conducted on an Intel Xeon 6 CPU (2.2 GHz, 2 vCPUs) in Google Colab without GPU to simulate low-resource deployment. EfficientNetV2B0 achieved the best performance with 99.62% validation accuracy and 99.79% test accuracy, with an average inference latency of 78 ms/frame. Compared to previous studies focusing on heavyweight models or conventional ML using handcrafted features, this work highlights the feasibility of deploying an accurate real-time diagnostic pipeline on edge devices.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Harkat Negeri
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Cat Skin Disease Diagnosis Using EfficientNetV2 for Lightweight Processing on Low-Resource Devices</dc:title>
	<dc:creator xml:lang="en">Aminah, Fadila Rizka Nur</dc:creator>
	<dc:creator xml:lang="en">Mutasodirin, Mirza Alim</dc:creator>
	<dc:creator xml:lang="en">Hidayattullah, Muhammad Fikri</dc:creator>
	<dc:subject xml:lang="en">cat skin</dc:subject>
	<dc:subject xml:lang="en">disease diagnosis</dc:subject>
	<dc:subject xml:lang="en">EfficientNetV2</dc:subject>
	<dc:subject xml:lang="en">feline skin</dc:subject>
	<dc:subject xml:lang="en">low-resource device</dc:subject>
	<dc:description xml:lang="en">Skin diseases are among the most common health issues in domestic cats. However, access to veterinarians is often limited, especially in low-resource settings. Automated image-based detection offers a fast and affordable alternative for early intervention. This paper presents a lightweight approach for diagnosing feline skin diseases using EfficientNetV2 optimized for low-resource devices. A balanced custom dataset consisting of 720 images across nine classes, namely Healthy, Mild/Severe Ringworm, Mild/Severe Acne, Mild/Severe Flea, and Mild/Severe Scabies, was compiled from Kaggle, Roboflow, and Google Images, ensuring ethical use of publicly available data. The images were augmented through rotations (0°, 90°, 180°, 270°) and horizontal flips, resulting in 5,760 images, to enhance model generalization. Five CNN architectures were benchmarked: DenseNet121, MobileNetV2, MobileNetV3, EfficientNetB0, and EfficientNetV2B0. Training was conducted with grid searches over batch sizes {64, 32, 16, 8} and learning rates {1e-3, 5e-4, 2e-4, 1e-4, 5e-5} for up to 300 epochs, and with the Adam optimizer and Reduce-LR-on-Plateau (decay factor 0.5). Early stopping (patience = 10) was used to mitigate overfitting. The best model was selected based on highest validation accuracy. The experiments were conducted on an Intel Xeon 6 CPU (2.2 GHz, 2 vCPUs) in Google Colab without GPU to simulate low-resource deployment. EfficientNetV2B0 achieved the best performance with 99.62% validation accuracy and 99.79% test accuracy, with an average inference latency of 78 ms/frame. Compared to previous studies focusing on heavyweight models or conventional ML using handcrafted features, this work highlights the feasibility of deploying an accurate real-time diagnostic pipeline on edge devices.</dc:description>
	<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
	<dc:date>2025-12-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/29764</dc:identifier>
	<dc:identifier>10.15294/jte.v17i2.29764</dc:identifier>
	<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 17 No. 2 (2025); 45-50</dc:source>
	<dc:source>2549-1571</dc:source>
	<dc:source>1411-0059</dc:source>
	<dc:source>10.15294/jte.v17i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/29764/7926</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>