Jurnal
Tanpa peringkat SINTA
Portable EMG System for IoT Using MQTT
Jurnal Teknik Elektro · Vol. 17 No. 2 (2024) · hlm. 57–63
ISSN 2549-1571, 1411-0059
Terbit 2024-12-30
Penerbit LPPM Universitas Negeri Semarang
Bahasa eng
Abstrak
Conventional electromyography (EMG) systems in clinical settings present limitations including high examination costs (500,000-1,500,000 IDR), bulky equipment, and lack of remote monitoring capabilities. This study develops and validates a portable Internet of Things (IoT)-based EMG system utilizing Message Queuing Telemetry Transport (MQTT) protocol for wireless muscle activity monitoring. The system integrates an EMG V3 sensor module with NodeMCU ESP8266 microcontroller, powered by dual 18650 batteries. Implementation utilized Arduino IDE and IoT MQTT Panel application. Validation comprised functional suitability testing (ISO/IEC 25010:2012), signal characteristics analysis across five subjects with 10 trials each, and repeatability precision evaluation (ISO 17025:2017). The system demonstrated 100% functional suitability. EMG signal characteristics showed average peak-to-peak voltage of 8.95±0.62 mV during relaxation and 10.48±0.58 mV during contraction, with Root Mean Square (RMS) voltage of 1.38±0.11 mV and 1.94±0.21 mV, respectively. Signal frequency-maintained consistency at approximately 50 Hz. Overall repeatability precision achieved 97.62%. This portable EMG system addresses conventional system limitations through wireless connectivity and reduced cost while maintaining measurement accuracy suitable for muscle health monitoring applications.
Jaringan kolaborasi para penulis
15 penulis ·
28 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Walisongo State Islamic University Sunan Kalijaga State Islamic University Yogyakarta Indonesian Institute of Sciences Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unnes.ac.id/journals/jte/oai, pertama di-harvest 6 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Portable EMG System for IoT Using MQTT</dc:title>
<dc:creator xml:lang="en">Yuniati, Anis</dc:creator>
<dc:creator xml:lang="en">Ramadhani, Bintang</dc:creator>
<dc:creator xml:lang="en">Rakhmadi, Frida Agung</dc:creator>
<dc:creator xml:lang="en">Sumarti, Heni</dc:creator>
<dc:subject xml:lang="en">electromyography</dc:subject>
<dc:subject xml:lang="en">EMG V3 sensor module</dc:subject>
<dc:subject xml:lang="en">internet of things (IoT)</dc:subject>
<dc:subject xml:lang="en">Message Queuing Telemetry Transport (MQTT)</dc:subject>
<dc:subject xml:lang="en">NodeMCU ESP8266</dc:subject>
<dc:description xml:lang="en">Conventional electromyography (EMG) systems in clinical settings present limitations including high examination costs (500,000-1,500,000 IDR), bulky equipment, and lack of remote monitoring capabilities. This study develops and validates a portable Internet of Things (IoT)-based EMG system utilizing Message Queuing Telemetry Transport (MQTT) protocol for wireless muscle activity monitoring. The system integrates an EMG V3 sensor module with NodeMCU ESP8266 microcontroller, powered by dual 18650 batteries. Implementation utilized Arduino IDE and IoT MQTT Panel application. Validation comprised functional suitability testing (ISO/IEC 25010:2012), signal characteristics analysis across five subjects with 10 trials each, and repeatability precision evaluation (ISO 17025:2017). The system demonstrated 100% functional suitability. EMG signal characteristics showed average peak-to-peak voltage of 8.95±0.62 mV during relaxation and 10.48±0.58 mV during contraction, with Root Mean Square (RMS) voltage of 1.38±0.11 mV and 1.94±0.21 mV, respectively. Signal frequency-maintained consistency at approximately 50 Hz. Overall repeatability precision achieved 97.62%. This portable EMG system addresses conventional system limitations through wireless connectivity and reduced cost while maintaining measurement accuracy suitable for muscle health monitoring applications.</dc:description>
<dc:publisher xml:lang="en">LPPM Universitas Negeri Semarang</dc:publisher>
<dc:date>2024-12-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unnes.ac.id/journals/jte/article/view/33839</dc:identifier>
<dc:identifier>10.15294/jte.v17i2.33839</dc:identifier>
<dc:source xml:lang="en">Jurnal Teknik Elektro; Vol. 17 No. 2 (2025); 57-63</dc:source>
<dc:source>2549-1571</dc:source>
<dc:source>1411-0059</dc:source>
<dc:source>10.15294/jte.v17i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.unnes.ac.id/journals/jte/article/view/33839/7918</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2025 Jurnal Teknik Elektro</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Yuniati, A., Ramadhani, B., Rakhmadi, F. A., & Sumarti, H. (2024). Portable EMG System for IoT Using MQTT. Jurnal Teknik Elektro, 17(2), 57–63. https://doi.org/10.15294/jte.v17i2.33839
Salin
IEEE
A. Yuniati, B. Ramadhani, F. A. Rakhmadi, and H. Sumarti, “Portable EMG System for IoT Using MQTT,” Jurnal Teknik Elektro, vol. 17, no. 2, pp. 57–63, 2024, doi: 10.15294/jte.v17i2.33839.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.