Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

A new exact equivalent circuit of the medium voltage three-phase induction motor

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 10 No. 6 (2020)

DOI
10.11591/ijece.v10i6.pp6164-6171
ISSN
2722-2578, 2088-8708
Published
2020-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This paper proposes a new equivalent circuit for medium voltage and great power induction motors considering the more complete information given by the manufacturer. A methodology for obtaining the parameters of the equivalent circuit is presented, having this circuit the advantage of allowing the electrical calculation of all the power losses and the realization of the power balance. It is an achievement of this work a new way of calculating and representing the additional losses using a resistance located in the rotor circuit. Then, three types of losses are considered as a part of a power balance: the conventional or joule effect variable losses, the constant losses, and the additional losses. The proposed method is straight and non-iterative. It was applied to a case study motor of 6000 V and 2500 kW located at the Maximo Gomez Power Plant in Cuba.

Collaboration network of the authors

18 authors · 46 co-authorship links · 24 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad de la Costa
  • University of Cienfuegos
  • Universidad Autónoma de Occidente
  • Universidad Simón Bolívar
  • University of Coimbra
  • Universidad Nacional de Río Cuarto
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Enrique Ciro QuispeUniversidad Autónoma de Occidente6
Julio Rafael Gómez SarduyUniversity of Cienfuegos3
Percy R. ViegoUniversity of Cienfuegos2
Hernán Hernández HerreraUniversidad Simón Bolívar1
Iván D. LópezUniversidad Autónoma de Occidente1
Fernando J. T. E. FerreiraUniversity of Coimbra1
Adrián Bolaño MartínezUniversidad de la Costa1
Isaac Jimenez NavarroUniversidad de la Costa1
Pablo D. DonoloUniversidad Nacional de Río Cuarto1
Percy Rafael Viego FelipeUniversity of Cienfuegos1
José Pedro Monteagudo YanesUniversity of Cienfuegos1
Eliana Noriega AngaritaUniversidad de la Costa1
Pablo Daniel DonoloAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A new exact equivalent circuit of the medium voltage three-phase induction motor</dc:title><dc:creator>Solar, Laura Collazo</dc:creator><dc:creator>Costa Montiel, Angel A.</dc:creator><dc:creator>Llanes, Miriam Vilaragut</dc:creator><dc:creator>Santos, Vladimir Sousa</dc:creator><dc:creator>Colina, Abel Curbelo</dc:creator><dc:description>&lt;jats:p&gt;This paper proposes a new equivalent circuit for medium voltage and great power induction motors considering the more complete information given by the manufacturer. A methodology for obtaining the parameters of the equivalent circuit is presented, having this circuit the advantage of allowing the electrical calculation of all the power losses and the realization of the power balance. It is an achievement of this work a new way of calculating and representing the additional losses using a resistance located in the rotor circuit. Then, three types of losses are considered as a part of a power balance: the conventional or joule effect variable losses, the constant losses, and the additional losses. The proposed method is straight and non-iterative. It was applied to a case study motor of 6000 V and 2500 kW located at the Maximo Gomez Power Plant in Cuba.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2020-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v10i6.pp6164-6171</dc:identifier><dc:identifier>10.11591/ijece.v10i6.pp6164-6171</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 10 No 6 (2020); 6164</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/22793/14403</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>